USE A-LOK SEAL OR APPROVED EQUAL COMPACTED CRUSHED STONE UNDISTURBED SOIL SDR26 OR DIP SIZE SAME AS RUN OF SEWER VARES SHAPE MANHOLE BOTTOM TO DRAIN CONCRETE ENCASEMENT 8" CONCRETE MANHOLE BASE NOTES 1. MINIMIZE DISTANCE TO UNDISTURBED SOIL AROUND DROP CONNECTION. 2. DROP CONNECTION TO BE USED FOR ALL PIPE ENTERING MANHOLES MORE THAN 24" ABOVE OUTLET PIPE. 3. FOR GENERAL DIMENSIONS OF MANHOLE, SEE TYPICAL MANHOLE DRAWING. SANITARY DROP CONNECTION FIGURE 8.3