Text read by the vision model; check the PDF for anything that matters.7'-9" 1/2" STAIR NOTE:
USE OF 11" X 11" PLYWOOD SUBFLOOR.
4 TREADS AT 12" EACH VERT.
12" DECK - 30" - 18" TOTAL
SEE VERIFY
8'-1" STAIR NOTE:
USE OF 11" X 11" PLYWOOD SUBFLOOR.
4 TREADS AT 12" EACH VERT.
12" DECK - 30" - 18" TOTAL
SEE VERIFY
8'-1" STAIR NOTE:
USE OF 11" X 11" PLYWOOD SUBFLOOR.
4 TREADS AT 12" EACH VERT.
12" DECK - 30" - 18" TOTAL
SEE VERIFY
9'-1" STAIR NOTE:
USE OF 11" X 11" PLYWOOD SUBFLOOR.
4 TREADS AT 12" EACH VERT.
12" DECK - 30" - 18" TOTAL
SEE VERIFY
- FOR ADDITIONAL NOTES SEE GENERAL NOTES ON TITLE SHEET AND DETAILS.
- SEE ELEVATIONS FOR FLOOR TO CEILING HEIGHTS.
- SEE ELEVATIONS FOR ELEVATOR SHAFTS.
- ALL OPENINGS TO WINDOWS AND DOORS ARE TO CENTERLINE.
WALL LEGEND:
KEY NOTES:
FIRE PROTECTION:
HOUSE TO GARAGE FIRE SEPARATION, GARAGE/HOUSE SEPARATION
AS PER LOCAL CODES (TYPICAL 1/2" GYPSUMBOARD, SEE LOCAL CODES)
GARAGE/HOUSE SEPARATION AT HORIZONTAL SURFACES
SMALL OPENINGS (LESS THAN 24" X 24") PROVIDE 1/2" GYPSUMBOARD
TYPICAL 1/2" GYPSUMBOARD, SEE LOCAL CODES
HOUSE TO GARAGE DOOR SEPARATION PROVIDE 1/2" SOLID
DOOR ASSEMBLY, SEE LOCAL CODES
RATED DOOR, SEE LOCAL CODES
INTERIOR STAIRS AND LANDINGS, SEE GYPSUM BOARD
STAIRS AND LANDINGS, SEE LOCAL ACCESSIBLE
AREA, SEE LOCAL CODES
HEATER, SEE LOCAL CODES
N/A
AG CONSIDER PAS RATING
PRE-FABRICATED METAL HEATERS
DETAILS, SEE MANUFACTURER'S INSTRUCTIONS
ATC ACCESS, REMOVABLE 27/32" PANEL
REMOVABLE CLEAR WOODWORK REVEAL ACCESS OPENING
TYPICALS:
IMMERSION SAFETY GLASS, SEE LOCAL CODES
FIREPLACE SHELF ABOVE MINIMUM WALL THIN OVER HEIGHT AS NOTED
WALL SHELL, SEE LOCAL CODES
INSULATED SINKS, SEE LOCAL CODES
SINKS, SEE LOCAL CODES
TOILET, SEE LOCAL CODES
N/A
ACRYLIC TUB IN CERAMIC PLATFORM
KITCHEN:
OPTIMAL 30" SINK IS BUILT-IN PACKAGE FOR BUILDER
SEE LOCAL CODES FOR INSTALLATION REQUIREMENTS
30" GAS COOKTOP AND OVEN
VITRIFIRE MANUFACTURER'S INSTALLATION REQUIREMENTS
ELECTRIC OVEN MANUFACTURER'S INSTALLATION REQUIREMENTS
1st Floor Plan 'A' at Opt Basement
FOR CONSTRUCTION
40' Series
X450
Master Set (Iowa)
D.R. HORTON
America's Builder
PROJECT: GMD-GARD40
MODEL: 'X450'
1st FLOOR
PLAN '4EGF'
PRINT DATE: Sept 20, 2019