ordinance · G-1,H-2

G-1, H-2 - Ordinance 2022-492 - Rezoning Prairie Village Part 3 - R-1A, R-2, R-4 to R-1D-OPD, R-2-OPD and R-4-OPD

Open the PDF Searchable (OCR) PDF

Page 25 of 64

Text read by the vision model; check the PDF for anything that matters.
BASEMENT NOTES: - ALL AREAS PERIMETERED AS SHOWN (SIZES OTHERWISE NOTED) - FOR ADDITIONAL NOTES SEE GENERAL NOTES ON TITLE SHEET AND DETAILS. - MINIMUM HEAD HEIGHTS: - BASEMENT CEILING TO ELEVATION - PROVIDE FIRESTOPPING, PER LOCAL CODES - MINIMUM SUPPLIER TO VERIFY AT LEAST ONE OPENING IN ALL DECKS TO HAVE A CLEAR OPENING OF AT LEAST 36" X 48" OR AN EQUIVALENT AREA OF 24" IN HEIGHT AND 20" IN WIDTH. SHALL NOT BE GREATER THAN 4" ABOVE FLOOR. PER LOCAL CODES - ALL EXPOSED STEEL TO BE FIELD PAINTED. ALL EXPOSED CONCRETE TO BE RELOCATED/PAINTED TO FIELD CONDITIONS. CONTRACTOR TO VERIFY. - REFER TO STRUCTURAL ENGINEERING DRAWINGS SHOWN ON THIS PLAN. - VERIFY ALL EXPOSED STEEL IS PROPERLY BRACED AND SUPPORTED. - SEE 1/2" MAX AT REINFORCING DOORS. PER LOCAL CODES. - SEE GARAGE DOOR OPENING SIZE AND LOCATION. SEE DETAIL "A" FOR GARAGE DOOR OPENING. - SEE GARAGE DOOR OPENING SIZE AND LOCATION. SEE DETAIL "B" FOR GARAGE DOOR OPENING. - SEE GARAGE DOOR OPENING SIZE AND LOCATION. SEE DETAIL "C" FOR GARAGE DOOR OPENING. - SEE GARAGE DOOR OPENING SIZE AND LOCATION. SEE DETAIL "D" FOR GARAGE DOOR OPENING. KEY NOTES: - LINE OF SLAB ABOVE - LINE OF EXPOSED WALL JOISTS - PROVIDE 1/2" X 1/2" X 1/2" LATH AND 1/2" OSB/HDF BOARD ON WALLS AND CEILINGS. SEE DETAIL "A" FOR ACCESSIBLE AREAS. PER LOCAL CODES - NA - SEE PILLAR/BEAM REBAR REINFORCEMENT SCHEDULE - SEE HEATER AND FLOOR DRAIN, SEE DETAIL "A" - SEE STORAGE SPACE INSTALL PER MANUFACTURER'S REQUIREMENTS. SEE DETAIL "A" FOR MECHANICAL SPACES - THREADED SAFETY GLASS, PER LOCAL CODES - SEE SHOWER COMBO - SEE FLOOR DRAINS, SEE PLUMBING AND CIVIL ENGINEERING DRAWINGS. SEE DETAIL "A" FOR SLOPE FLOORING FROM WALLS TO DOWN TO FLOOR CROSS SLOPE 7'-4 1/2" STAIR NOTE: USE #1 TREADS AT 17" EACH (STAIR) #1 RISERS AT 7 5/8" = 12' 4" TOTAL SEE DETAIL "A" 8'-4 1/2" STAIR NOTE: USE #1 TREADS AT 17" EACH (STAIR) #1 RISERS AT 7 5/8" = 12' 4" TOTAL SEE DETAIL "A" COMPLIANCE OF FIRE PROTECTION OF FLOORS PER DETAIL "A" (SECTION 522 B) STAIRS/STAIRWELL ARE TO BE PER LOCAL CODES unfinished basement 7'-4 1/2" clg Opt Look-Out Basement Plan unfinished basement 7'-4 1/2" clg Opt Walk-Out Basement Plan GARAGE SLAB REINFORCE FOR LOCAL CODE AND ENGINEER SPECIFICATION. GARAGE SLAB REINFORCE FOR LOCAL CODE AND ENGINEER SPECIFICATION. Opt Oversized 3 Car Garage Opt 3rd Car Garage

Sources

  • sharepoint (G-1, H-2 - Ordinance 2022-492 - Rezoning Prairie Village Part 3 - R-1A, R-2, R-4 to R-1D-OPD, R-2-OPD and R-4-OPD.pdf) — where it was found ↗ first seen Oct 12, 2026

This document's details as JSON

Data last updated October 16, 2026. Built from the archive's documents; see how the data is built.