contract agreement · E-3

Approval of Change Order #3 – Tricon Construction Group – Water Treatment Facility Upgrade — E-3

Dated September 1, 2026City Council — regular meeting, September 1, 2026 72 pages

Open the PDF Searchable (OCR) PDF

Page 6 of 72

Text read by the vision model; check the PDF for anything that matters.
F SERIES Frame Construction 12, 14, or 16 gauge, color-coated, galvanized (G90) steel to be brake-formed to the design specifications required. (See pages F-3 TO F-9 for sizes and profiles available). Frames shall be furnished knock-down or welded, ground smooth upon request. Mitered corners shall have a strong, secure, four tab interlocking system to maintain neat mitered joints and corners. Standard frame to have 1/2" returns; standard stop heights to be 5/8" high. Soffit dimensions can vary. Frames can be single or double rabbed. Frames will be supplied with welded on sill anchors. (Note: Bending tabs in on the jamb rabbets will increase door opening dimension). Installation & Applications Frames to be installed in accordance with ANSI A250.13-2001. Standard series frames to be used in a number of applications including masonry, wood stud and steel stud construction. Hardware Reinforcements Frames to be furnished with 4-1/2" or 5" standard or heavy weight 7 gauge steel hinge reinforcements and shall be adequately reinforced for all hardware. Standard arm or parallel closer reinforcements available upon request. Strike and hinge reinforcements shall be protected by mortar guards. Single frames shall be prepared to receive (3) rubber mutes. Finish Exposed frame surfaces to be cleaned and treated then coated with rust inhibitive primer. Color painted frames to receive a durable, flow coated, baked on finish. Water-based primer and color paint finishes to be free of Hazardous Air Pollutants (HAPS) and Volatile Organic Compounds (VOCs). Compliance All Mesker frame components comply with ANSI A250.8(R2008). Fire labeling in accordance NFPA and available in FM (standard), WHI (Intertek) and Underwriters Laboratories. For a complete list of product compliance per ANSI/ASTM test methods, consult the labeling section. Non-Reated KD Frame Specifications Frames for 1/8" (standard) and 1/2" (special) steel thicknesses to be manufactured from 12, 14, or 16 gauge galvanized (G90) steel by Edgewater Door, Menomonee, Wisconsin. Profile shall be formed to provide a strong, secure, four tab interlocking system to maintain neat mitered joints and corners. Standard frame to have 1/2" returns; standard stop heights to be 5/8" high. Soffit dimensions can vary. Frames can be single or double rabbed. Frames will be supplied with welded on sill anchors. (Note: Bending tabs in on the jamb rabbets will increase door opening dimension). 90 Minute Fire-rated Frame Specifications Frames for 1/8" (standard) series fiberglass frames to be manufactured from 0.187 inch (4.8mm) thick fiberglass reinforced by Edgewater Door. Nominal 1/8" (4.8mm) thickness is standard hollow core type, or insulated and vapor permeable hollow core type. Frames shall be provided with mitered corners, double and countersunk for 1/2 wood screws. Supplied with (4) KDP color coat of choice. Frames shall be prepped and secured with 3/4" stainless wood screws. All, 4-1/2" or 5" standard or heavy weight 7 gauge, 90 minute fire rated, labeled and approved. It is the End User's responsibility to ensure all components used in the openings meet or exceed all fire ratings required.

Sources

Attached to agenda item: E-3 Approval of Change Order #3 – Tricon Construction Group – Water Treatment Facility Upgrade

This document's details as JSON

Data last updated October 15, 2026. Built from the archive's documents; see how the data is built.