Subject: RE: Tiffin WTP Low Lift Pumps - 0915659
Gary,
In addition to what you stated below, Hydraulic Institute has an exception on e2iciency with pump power input of
10kw (13hp) or less. See attached.
Thanks,
Eric Nead
Direct +1 913.748.4147
Mobile +1 913.291.9386
Confidentiality Note: This email may contain confidential information intended for the use of the addressees named above. If you are not the intended
recipient of this email, you are hereby notified that you must not disseminate, copy or take any action in respect of any information contained in it. If you
have received this email in error, please notify the sender immediately by email and immediately destroy this email and its attachments.
From: Gary Ganoe <[email protected]>
Sent: Tuesday, February 3, 2026 11:30 AM
To: Clint Wienen <[email protected]>
Cc: Nead, Eric <[email protected]>; Lyons, Douglas <[email protected]>; [email protected]
Subject: RE: Tiffin WTP Low Lift Pumps
Clint,
Andrew Larson provided part of the explanation:
Testing is done with TEST motors unless specifically called out with JOB motor.
The test motors have known e iciency and power factor. Some refer to them as Calibrated motors.
Submittals are generally calculated e iciency. Tend to be per a 2B grade.
If a specific e iciency is called out to a specific Hydraulic Institute Grade it will be noted on the
curve. Quality control will evaluate per the noted call outs.
What I do see is the submitted pump is Non Overloading 10HP.
6