4. Steam, hot or chilled water piping within any heating or cooling equipment regulated by this code. 5. Replacement of any minor part that does not alter approval of equipment or make such equipment unsafe. 6. Portable evaporative coolers. 7. Self-contained refrigeration systems containing 10 pounds (4.54 kg) or less of refrigerant or that are actuated by motors of 1 horsepower (746 W) or less. 8. Portable-fuel-cell appliances that are not connected to a fixed piping system and are not interconnected to a power grid. Plumbing: 1. The stopping of leaks in drains, water, soil, waste or vent pipe; provided, however, that if any concealed trap, drainpipe, water, soil, waste or vent pipe becomes defective and it becomes necessary to remove and replace the same with new material, such work shall be considered as new work and a permit shall be obtained and inspection made as provided in this code. 2. The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures, and the removal and reinstallation of water closets, provided such repairs do not involve or require the replacement or rearrangement of valves, pipes or fixtures. R105.5 Amend Sections 105.5 and 105.5R by adding the following sentence to the end of the section: In no case shall the permit be effective unless the work covered by the permit has a documented inspection every 180 days minimum and is completed within 24 months of the date on which the original permit was issued. 8. Modify the following Sections from Chapter Three of the IRC and inserting the following: R301.2 Climatic and geographic design criteria. Buildings shall be constructed in accordance with the provisions of this code as limited by the provisions of this section. Additional criteria shall be established by the local jurisdiction and set forth in Table R301.2 (1). <table> <tr> <th rowspan="2">Ground Snow Load</th> <th rowspan="2">Wind Speed MPH</th> <th rowspan="2">Seismic Design Category</th> <th colspan="5">Subject To Damage From</th> <th rowspan="2">Ice Shield Underlayment Required</th> <th rowspan="2">Flood Hazards</th> <th rowspan="2">Air Freezing Index</th> <th rowspan="2">Mean Annual Temp</th> </tr> <tr> <th>Frost Line Depth</th> <th>Weathering</th> <th>Termite</th> <th>Decay</th> <th>Winter Design Temp</th> </tr> <tr> <td>25</td> <td>115</td> <td>A</td> <td>Severe</td> <td>42"</td> <td>M – H</td> <td>S – M</td> <td>-5° F</td> <td>Yes</td> <td>2/16/07</td> <td>2000</td> <td>50 F</td> </tr> </table> Table R301.2(1) Climatic and Geographic Design Criteria MANUAL J DESIGN CRITERIA <table> <tr> <th>Elevation</th> <th>Latitude</th> <th>Winter Heating</th> <th>Summer Cooling</th> <th>Altitude Correction Factor</th> <th>Indoor Design Temperature</th> <th>Design Temperature Cooling</th> <th>Heating Temperature Difference</th> </tr> <tr> <td>661'</td> <td>41</td> <td>-6</td> <td>89</td> <td>N/A</td> <td>72</td> <td>75</td> <td>78</td> </tr> <tr> <td>Cooling Temperature Differences</td> <td>Wind Velocity Heating</td> <td>Wind Velocity Cooling</td> <td>Coincident Wet Bulb</td> <td>Daily Range</td> <td>Winter Humidity</td> <td>Summer Humidity</td> <td></td> </tr> <tr> <td>14</td> <td>25</td> <td>10</td> <td>76</td> <td>M</td> <td>39 gr/lb diff</td> <td>53 gr/lb diff</td> <td></td> </tr> </table>

Sources

  • laserfiche: Ordinances-2019-458 - Chapter 106 & Chapter 156 (Ordinances-2019-458 - Chapter 106 & Chapter 156.pdf) — where it was found ↗ first seen Oct 12, 2026

This document's details as JSON

Data last updated October 15, 2026. Built from the archive's documents; see how the data is built.