packet

Packet: Tiffin Regular City Council Meeting (09/01/2026)

Open the PDF Searchable PDF tesseract layer

Page 138 of 184

Text read by the vision model; check the PDF for anything that matters.
<table> <tr> <th>Application No.: 12R</th> <th>Application Period:</th> <th>From</th> <th>07/24/26</th> <th>to</th> <th>08/21/26</th> <th>Application Date:</th> <th>08/21/26</th> </tr> <tr> <td>180</td> <td>Bldg 10 - Foundations (Exc&BF)</td> <td>$25,630.00</td> <td>25,630.00</td> <td></td> <td></td> <td>25,630.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>181</td> <td>Bldg 20 - RO Fundations (Exc&BF)</td> <td>$45,250.00</td> <td>45,250.00</td> <td></td> <td></td> <td>45,250.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>182</td> <td>Bldg 20 - Aeration Tank Found (Ex&BF)</td> <td>$15,640.00</td> <td>15,640.00</td> <td></td> <td></td> <td>15,640.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>183</td> <td>Bldg 30 - Foundations (Exc&BF)</td> <td>$37,650.00</td> <td>18,825.00</td> <td>16,942.50</td> <td></td> <td>35,767.50</td> <td>95%</td> <td>1,882.50</td> </tr> <tr> <td>184</td> <td></td> <td></td> <td>-</td> <td></td> <td></td> <td>-</td> <td>-</td> <td>-</td> </tr> <tr> <td>185</td> <td><b>Exterior Improvements</b></td> <td></td> <td></td> <td></td> <td></td> <td></td> <td></td> <td></td> </tr> <tr> <td>186</td> <td>Asphalt Paving (Trail)</td> <td>$22,130.00</td> <td>22,130.00</td> <td></td> <td></td> <td>22,130.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>187</td> <td>Concrete Paving (Site)</td> <td>$130,288.00</td> <td></td> <td>97,716.00</td> <td></td> <td>97,716.00</td> <td>75%</td> <td>32,572.00</td> </tr> <tr> <td>188</td> <td>Chain Link Fencing</td> <td>$32,250.00</td> <td></td> <td></td> <td></td> <td>-</td> <td>0%</td> <td>32,250.00</td> </tr> <tr> <td>189</td> <td>Seeding</td> <td>$6,914.00</td> <td></td> <td></td> <td></td> <td>-</td> <td>0%</td> <td>6,914.00</td> </tr> <tr> <td>190</td> <td></td> <td></td> <td></td> <td></td> <td></td> <td>-</td> <td>-</td> <td>-</td> </tr> <tr> <td>191</td> <td><b>Utilities</b></td> <td></td> <td></td> <td></td> <td></td> <td></td> <td></td> <td></td> </tr> <tr> <td>192</td> <td>A - 12" W to Clearwell</td> <td>$32,544.00</td> <td>29,289.60</td> <td></td> <td></td> <td>29,289.60</td> <td>90%</td> <td>3,254.40</td> </tr> <tr> <td>193</td> <td>B - 8" W to Clearwell</td> <td>$25,663.00</td> <td>25,663.00</td> <td></td> <td></td> <td>25,663.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>194</td> <td>C - UG Storm Sewer North</td> <td>$48,686.00</td> <td>38,948.80</td> <td></td> <td></td> <td>38,948.80</td> <td>80%</td> <td>9,737.20</td> </tr> <tr> <td>195</td> <td>D - 12" W Aerator to Clearwell</td> <td>$18,549.00</td> <td>18,549.00</td> <td></td> <td></td> <td>18,549.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>196</td> <td>E - 12" W Bldg 10 to Bldg 20</td> <td>$8,554.00</td> <td>7,698.60</td> <td></td> <td></td> <td>7,698.60</td> <td>90%</td> <td>855.40</td> </tr> <tr> <td>197</td> <td>G - UG Storm Sewer East</td> <td>$67,822.00</td> <td>67,822.00</td> <td></td> <td></td> <td>67,822.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>198</td> <td>H & J - UG Storm Sewer West/South</td> <td>$87,552.00</td> <td>87,552.00</td> <td></td> <td></td> <td>87,552.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>199</td> <td>K - UG Storm Sewer Clearwell West</td> <td>$42,500.00</td> <td></td> <td></td> <td></td> <td>-</td> <td>0%</td> <td>42,500.00</td> </tr> <tr> <td>200</td> <td>F - UG Sanitary Manholes & Piping</td> <td>$165,835.00</td> <td>165,835.00</td> <td></td> <td></td> <td>165,835.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>201</td> <td>Roof Drains</td> <td>$2,500.00</td> <td>2,000.00</td> <td>500.00</td> <td></td> <td>2,500.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>202</td> <td>Bldg 20 - Process Drain Manhole</td> <td>$8,500.00</td> <td>8,500.00</td> <td></td> <td></td> <td>8,500.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>203</td> <td></td> <td></td> <td></td> <td></td> <td></td> <td>-</td> <td>-</td> <td>-</td> </tr> <tr> <td>204</td> <td><b>Process Integration (Piping)</b></td> <td></td> <td></td> <td></td> <td></td> <td></td> <td></td> <td></td> </tr> <tr> <td>205</td> <td><b>Structure 10 - Existing Bldg</b></td> <td></td> <td></td> <td></td> <td></td> <td></td> <td></td> <td></td> </tr> <tr> <td>206</td> <td>Process Piping Materials</td> <td>$55,103.74</td> <td></td> <td>17,745.00</td> <td></td> <td>17,745.00</td> <td>32%</td> <td>37,358.74</td> </tr> <tr> <td>207</td> <td>Process Piping Labor</td> <td>$37,550.00</td> <td></td> <td></td> <td></td> <td>-</td> <td>0%</td> <td>37,550.00</td> </tr> <tr> <td>208</td> <td>Valves Materials</td> <td>$9,500.00</td> <td></td> <td>9,500.00</td> <td></td> <td>9,500.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>209</td> <td>Valves Labor</td> <td>$8,250.28</td> <td></td> <td></td> <td></td> <td>-</td> <td>0%</td> <td>8,250.28</td> </tr> <tr> <td>210</td> <td><b>Structure 20 - RO Building</b></td> <td></td> <td></td> <td></td> <td></td> <td></td> <td></td> <td></td> </tr> </table>

Sheets in this document

  • p. 16 plan sheet
  • p. 21 10A102 · Proposed Floor Plan · MSA · Water Treatment Facility Upgrade
  • p. 24 Weatherstripping - Jamb Weatherstripping
  • p. 25 Certifications: *Unnotched & Notched profiles available
  • p. 26 Thresholds - Saddle
  • p. 35 20P102 · Proposed Plumbing Above Grade Floor Plan · MSA · Water Treatment Facility Upgrade
  • p. 36 20H101 · RO Building HVAC Plan · MSA · Water Treatment Facility Upgrade
  • p. 45 10A100 · Safety Plan · MSA · Overall Facility
  • p. 46 10A101 · Life Safety Plan · MSA
  • p. 47 Floor Limits (Graphical · MSA
  • p. 48 20A101 · Architectural Floor Plan · MSA · 2 Painted Pipe Bollard
  • p. 49 Plan Review Comm · MSA · Proposed
  • p. 50 Typical Architectural Details · MSA
  • p. 51 Typical Details and Schedule Architectural Schedules · MSA
  • p. 52 20H101 · RO Building HVAC Plan · MSA · Water Treatment Facility Upgrade
  • p. 53 99H601 · HVAC Schedules · MSA
  • p. 54 20P102 · Proposed Plumbing Above Grade Floor Plan · MSA · Water Treatment Facility Upgrade
  • p. 55 20S101 · Foundation Plan · MSA · Water Treatment Facility Upgrade
  • p. 56 L-1 · Lintel Schedule · MSA · Mezzanine Framing
  • p. 57 Typical Structural Details · MSA
  • p. 58 MSA
  • p. 62 Power Plan · MSA
  • p. 77 EJ1A · Roof Trusses Layout
  • p. 78 MT20 · 2 Carpenters for 1 hrs each to layout, cut
  • p. 79 MT20 · 2 Carpenters for 2 hrs each to layout, cut
  • p. 80 Job Truss Truss Type Qty Ply Tiffin Water Treatment Plant / Structure 20 (chart; data on p. 78)
  • p. 82 MT20 · Notes
  • p. 160 Exhibit A: Project Location

Sources

  • revize: Agenda packet (packet_2026-09-01_3ad1ee37-4af1-4a67-8983-cc30e19b0f9e.pdf) — where it was found ↗ first seen Oct 12, 2026

This document's details as JSON

Data last updated October 20, 2026. Built from the archive's documents; see how the data is built.