other · C

Discussion and Review of Tiffin Municipal Code Revisions – Preparation for Setting the Public Hearing — Tiffin City Code - DRAFT

Open the PDF Searchable (OCR) PDF

Page 377 of 718

Text from the PDF text layer; check the PDF for anything that matters.
CHAPTER 158 SUDAS Stop boxes shall be A.Y. MCDONALD #5607L with stainless steel operating rod, or approved equal. Stop box cap shall have removable brass access plug. Preferences will be made for domestically made products and materials.” Article 3.01 A. 8. Add the following statement. “Thrust blocks as part of water main installation shall be precast. Poured-in-place thrust blocks are prohibited.” Article 3.05 H. Add the following Jurisdictional Requirements. “H. The above tracer wire system requirements shall also apply to water service piping. Tracer wire shall be installed with the service piping from the water main to the building that is being served. Tracer ware shall be tied into the tracer wire system of the watermain.” B. Section 5020 Valves, Fire Hydrants, and Appurtenances. Article 1.08. Make the following changes 1.08 A. Valve (Butterfly or Gate) “1.08 A.3 Includes: “Unit price also includes furnishing all labor, materials, and equipment necessary to install Valves Box Adaptor II, manufactured by Adaptor Inc., or approved equal, with all proposed valve boxes.” 1.08 B. Tapping Valve Assembly. 1.08 B.3 Includes: “Unit price also includes furnishing all labor, materials, and equipment necessary to install Valves Box Adaptor II, manufactured by Adaptor Inc., or approved equal, with the valve box.” 1.08 C. Fire Hydrant Assembly. 1.08 C.3 Includes: “Unit price also includes furnishing all labor, materials, and equipment necessary to install Valves Box Adaptor II, manufactured by Adaptor Inc., or approved equal, with the valve box.” 1.08 H. Valve Box Replacement. 1.08 H.3 Includes: “Unit price also includes furnishing all labor, materials, and equipment necessary to install Valves Box Adaptor II, manufactured by Adaptor Inc., or approved equal, with all replaced valve boxes.” CODE OF ORDINANCES, TIFFIN, IOWA - 1381 -

Sources

  • revize: Tiffin City Code - DRAFT (gFbbE0YR86eHDItZtXhZZqxLfknUlz.pdf) — where it was found ↗ first seen Oct 12, 2026

Attached to agenda item: C Discussion and Review of Tiffin Municipal Code Revisions – Preparation for Setting the...

This document's details as JSON

Data last updated October 17, 2026. Built from the archive's documents; see how the data is built.