Text from the PDF text layer; check the PDF for anything that matters.CHAPTER 156 HOUSING CODE
12. Fire Protection Equipment. All fire extinguishers and early warning fire
protection systems shall be properly installed according to the City Fire Code.
156.18 MINIMUM STRUCTURE STANDARDS FOR ALL RENTAL HOUSING.
1. Direct Access. Access to each dwelling unit or rooming unit shall not require
first entering any other dwelling unit or rooming unit, except access to rooming units
may be through a living room or kitchen of a unit occupied by the owner-operator of
the structure. No dwelling, dwelling unit or rooming unit containing two or more
sleeping rooms shall have such room arrangements that access to a bathroom or water
closet compartment intended for use by occupants of more than one sleeping room or
Type III dwelling unit is available only by going through another sleeping room or
Type III dwelling unit, nor shall room arrangements be such that access to a sleeping
room or Type III dwelling unit is available only by going through another sleeping
room or Type III dwelling unit. A bathroom or water closet compartment shall not be
used as the only passageway to any habitable room, hallway, basement, or cellar or to
the exterior of the dwelling unit or rooming unit.
2. Lighting of Public Halls and Stairways.
A. Public passageways and stairways in dwellings accommodating two
to four dwelling units or rooming units shall be provided with a convenient
wall-mounted light switch which activates an adequate lighting system.
B. Public passageways and stairways in buildings accommodating more
than four dwelling units or rooming units shall be lighted at all times with an
adequate artificial lighting system, except such artificial lighting may be
omitted from sunrise to sunset where an adequate natural lighting system is
provided. Whenever the occupancy of a building exceeds 100 persons, the
artificial lighting system as required herein shall be on an emergency circuit.
3. Fire Extinguishers. Fire extinguishers which are approved by the Fire
Marshal shall be provided within every single-family dwelling, dwelling unit within a
duplex, and dwelling unit within a multiple dwelling. Multiple dwellings shall have
fire extinguishers located within each laundry room and central mechanical room;
except where these rooms are contiguous, they may be served by one fire
extinguisher. Laundry rooms and central mechanical rooms which are equipped with
an automatic sprinkler system are exempt. The minimum size fire extinguisher is a 2-
A 10-B:C. Fire extinguishers must be properly mounted and in an area of easy access.
Fire extinguishers with a classification less than 2-A 10-B:C or lacking an ABC rating
shall be replaced with a 2-A 10-B:C or larger unit by July 31, 1994. Rooming houses
are required to have a 2-A 10-B:C rated fire extinguisher supplied on each floor level,
including habitable basement areas, and in each kitchen. Fire extinguishers supplied
in areas of public access shall be contained within an approved tamper-proof cabinet.
4. Early Warning Fire Protection System. All dwelling units and rooming units
shall be provided with smoke detectors as approved by the Building Official. Smoke
detectors shall be installed in accordance with the manufacturer’s instructions.
Dwelling units shall have smoke detectors located on each floor level, including
basements. Multi-family and rooming houses shall have smoke detectors in each
dwelling unit or rooming unit and in common corridors, stair towers, and stairways
constructed prior to 1978. Smoke detectors shall be operable at all times, and when
actuated, the detector shall provide an alarm for the dwelling unit or rooming unit. An
owner or owner’s agent of a multiple unit residential building, rooming house, duplex,
CODE OF ORDINANCES, TIFFIN, IOWA