Text from the PDF text layer; check the PDF for anything that matters.CHAPTER 156 HOUSING CODE
distance apart equivalent to at least 25 percent of the perimeter of the room.
Every such outlet and fixture shall be properly installed.
B. Every habitable room, toilet room, bathroom, laundry room, furnace
room, basement, and cellar shall contain at least one supplied ceiling- or wall-
type electric light fixture or switched outlet. Every such outlet and fixture
shall be properly installed.
C. Temporary wiring or extension cords shall not be used as permanent
wiring.
11. Minimum Space, Use and Location Requirements.
A. Floor Area Per Occupant:
(1) Every dwelling unit shall contain at least 120 square feet of
habitable floor space for the first occupant thereof and at least 100
additional square feet of habitable floor space for every additional
occupant thereof.
(2) For the purpose of determining the maximum permissible
occupancy, the floor area of that part of a room where the ceiling
height is less than five feet shall not be considered when computing
the total floor area of the room.
B. Maximum Occupancy. Not more than one family, plus that number
of roomers permitted in the Zoning Ordinance, except for guests, shall occupy
a dwelling unit unless a rental permit for a rooming house has been granted.
C. Sleeping Rooms. In every dwelling unit of two or more rooms and
every rooming unit, every room occupied for sleeping purposes by one
occupant shall contain at least 70 square feet of floor space, and every room
occupied for sleeping purposes by more than one occupant shall contain at
least 40 square feet of floor space for each additional occupant thereof, except
two-bedroom manufactured housing shall be required to have only one
bedroom in compliance with this section.
D. Ceiling Height. The ceiling height of every habitable room shall be at
least seven feet.
(1) In any habitable room where the ceiling is a part of a sloping
roof, at least one-half of the floor area shall have a ceiling height of at
least seven feet. Floor area, as stated above, means the area of the
floor where the vertical measurement from floor to ceiling is five feet
or more.
(2) Obstructions of space by such items as water and gas pipes
and cabinetry shall be permitted when such obstructions are located
within two feet of a partition or wall, do not interfere with normal
ingress and egress, would not interfere with an emergency ingress or
egress, and are approved by the Inspector. Obstruction of ceiling
space shall be permitted when such obstruction is located at a height
of not less than six feet, four inches from the floor and which does not
occupy more than 25 percent of the cubic area of the space within a
room further than six feet, four inches from the floor.