Text from the PDF text layer; check the PDF for anything that matters. D. No fuel burning furnace shall be located within any sleeping room or bathroom
unless provided with adequate ducting for air supply from the exterior, and the
combustion chamber for such heating unit shall be sealed from the room in an airtight
manner. Fuel burning water heaters are prohibited in bathrooms and sleeping rooms.
E. Every steam or hot water boiler and every water heater shall be protected against
overheating by appropriate pressure and temperature limit controls. Such controls shall
have a properly installed extension pipe on the pressure temperature control valve.
F. Every fuel burning space heating unit and water heater shall be equipped with an
electronic ignition or with a pilot light and an automatic control to interrupt the flow of
fuel to the unit in the event of a failure of the ignition device. All such heating units shall
have a limit control to prevent overheating.
10. Electrical Requirements.
A. Every habitable room shall contain at least two separate floor- or wall-type
electric double convenience outlets which shall be situated a distance apart equivalent to
at least 25 percent of the perimeter of the room. Every such outlet and fixture shall be
properly installed.
B. Every habitable room, toilet room, bathroom, laundry room, furnace room,
basement, and cellar shall contain at least one supplied ceiling- or wall-type electric light
fixture or switched outlet. Every such outlet and fixture shall be properly installed.
C. Temporary wiring or extension cords shall not be used as permanent wiring.
11. Minimum Space, Use and Location Requirements.
A. Floor Area Per Occupant:
(1) Every dwelling unit shall contain at least 120 square feet of habitable
floor space for the first occupant thereof and at least 100 additional square feet of
habitable floor space for every additional occupant thereof.
(2) For the purpose of determining the maximum permissible occupancy, the
floor area of that part of a room where the ceiling height is less than five feet
shall not be considered when computing the total floor area of the room.
B. Maximum Occupancy. Not more than one family, plus that number of roomers
permitted in the Zoning Ordinance, except for guests, shall occupy a dwelling unit unless
a rental permit for a rooming house has been granted.
C. Sleeping Rooms. In every dwelling unit of two or more rooms and every
rooming unit, every room occupied for sleeping purposes by one occupant shall contain
at least 70 square feet of floor space, and every room occupied for sleeping purposes by
more than one occupant shall contain at least 40 square feet of floor space for each
additional occupant thereof, except two-bedroom manufactured housing shall be required
to have only one bedroom in compliance with this section.
D. Ceiling Height. The ceiling height of every habitable room shall be at least seven
feet.
(1) In any habitable room where the ceiling is a part of a sloping roof, at
least one-half of the floor area shall have a ceiling height of at least seven feet.
Floor area, as stated above, means the area of the floor where the vertical
measurement from floor to ceiling is five feet or more.