Page 14 of 26
Text from the PDF text layer; check the PDF for anything that matters. (1) Every window or other device with openings to the outdoor space, used
for ventilation, shall be supplied with screens of not less than 16 mesh per inch.
(2) The total openable window area, as measured between stops, in every
habitable room shall be equal to at least four percent of the floor area of such
room.
(3) Every door opening directly from a dwelling unit or rooming unit to
outdoor space, the use of which is necessary to meet the minimum ventilation
requirements of this Code, shall have a supplied screen or screens and a self-
closing device.
(4) Every cellar window, soffit or roof vent used or intended to be used for
ventilation and every other opening to a cellar, crawl space, or interior roof area
which might provide an entry for rodents or birds shall be supplied with a heavy
wire screen of not larger than one-fourth inch mesh or such device as will
effectively prevent entrance.
(5) For natural ventilation, every bathroom or toilet compartment shall have
at least one openable window facing directly to the outdoors and at least 45
percent of the window must be openable.
C. Mechanical Ventilation.
(1) In lieu of openable windows for natural ventilation, adequate ventilation
may be a system of mechanical ventilation which provides not less than two air
changes per hour in all habitable rooms and/or bathrooms or toilet compartments.
(2) No mechanical exhaust system exhausting vapors, gases, or odors shall
be discharged into an attic, crawl space, or cellar unless such attic, crawl space,
or cellar is adequately vented to the outside.
(3) Any kitchen or kitchenette lacking natural ventilation shall be equipped
with a system of mechanical ventilation which provides at least two air changes
per hour in said room. The system shall exhaust and discharge directly to outside
air.
9. Heating.
A. Every dwelling shall have heating facilities which are properly installed and are
capable of safely and adequately heating all habitable rooms, bathrooms, and toilet rooms
located therein to a temperature of at least 68 degrees Fahrenheit and shall be capable of
maintaining in all said locations a minimum temperature of 65 degrees Fahrenheit at a
distance of three feet above the floor level at all times. Such heating facilities shall be so
designed and equipped that heat, as herein specified, is available for all dwelling units
and rooming units.
B. Every central heating unit, space heater, water heater, and cooking appliance
shall be located and installed in such a manner so as to afford reasonable protection
against involvement of egress facilities or egress routes in the event of uncontrolled fire
in the structure.
C. Every fuel burning heating unit or water heater shall be effectively vented in a
safe manner to a chimney or duct leading to the exterior of the building. The chimney,
duct, and vent shall be of such design as to assure proper draft and shall be adequately
supported.