Page 24 of 25
Text from the PDF text layer; check the PDF for anything that matters.The Statewide Urban Design and Specifications (SUDAS) Standard Specifications Manual shall be adopted
with the following additions:
Traffic Control: Complete; Lump Sum (LS);
The Contractor shall accommodate and maintain access to all residential and commercial
properties, unless approved by Engineer and Property Owner/Residents when not practical to do
such until the construction activity has been completed. All traffic control shall be in accordance
with the Iowa Department of Transportation Standard Specifications for Highway and Bridge
Construction, Series 2015 (current revision) and the Manual on Uniform Traffic Control Devices
(MUTCD). The contractor shall erect and maintain construction and warning signage, barricades,
fencing, and delineating devices to ensure the safety of the traveling public through and around the
jobsite. Contractor shall cover all permanent signage that is in conflict with or displays
information that is contradictory to the construction signage. Unit price includes but is not limited
to furnishing all labor, materials and equipment necessary to furnish, install, erect, maintain,
move, and remove construction and warning signage, in accordance with the Plans, of Iowa
Department of Transportation Standard Specifications for Highway and Bridge Construction,
Series 2012 (current revision) and MUTCD, assuring safe traffic flow.
Light Poles, Electrical Circuits, Handholes & Junction Boxes (Highway Lighting)
In general Light Poles, Electrical Circuits, Handholes and Junction Boxes shall be in accordance
with Section 2523 of Iowa Department of Transportation Standard Specifications for Highway and
Bridge Construction, Series 2015 (current revision).
All materials shall meet the City Design Standards.
Light poles shall consist of a metal pole of sufficient length such that the mounting of the
luminaire is not less than 26 feet or more than 30 feet above the roadway surface.
Mast arm shall be galvanized steel.
Lighting fixture shall contain an LED light source with a minimum of 8,500 lumens (ASA, Type
III) and shall meet Illumination Engineering Society (IES) Type II “sharp cutoff” lighting criteria
(limited “fugitive light” and direct downward illumination).