Text from the PDF text layer; check the PDF for anything that matters. b. Particulate Matter
The rate of emission of particulate matter from all sources within the
boundaries of any lot must not exceed the rate established in the
following Table:
c. Maximum Permitted Particulate Matter Emission Rate
Height of Emission Pounds Per Hour
(Feet) Per Acre
0 through 49 1.00
50 through 99 1.01
100 through 149 1.06
150 through 199 1.10
200 through 299 1.16
300 through 399 1.30
400 and over 1.50
d. Method of Measurement-
i. Smoke – To grade the density or equivalent opacity of
emission of smoke, the Ringelmann Chart must be used. To
determine smoke units, the Ringelmann reading must be made
at least every minute during the period of observation. Each
reading (Ringelmann number) must be multiplied by the time in
minutes that it is observed, and the products added together to
determine the total number of smoke units observed during the
total period of observation.
ii. Particulate Matter - The total net rate of emission of
particulate matter within the boundaries of any lot must be
determined as follows: Determine the maximum emission in
pounds per hour from each source of emission and divide this
figure by the number of acres of lot area, thereby obtaining the
hourly rate of emission in pounds per acre. Add together the
individual rates of emission as derived above to obtain the total
rate of emission from all sources of emission within the
boundaries of the lot. This total must not exceed the rate
established in the preceding Table.
4. Odors
Continuous, frequent, or repetitive emission of odors or odor-causing substances
that would be offensive beyond any property line of any industrial use are
prohibited. An odor emitted no more than 15 minutes in any one day must not be
deemed as continuous, frequent, or repetitive within the meaning of these
regulations. The existence of an odor is presumed when analysis by a competent
technician demonstrates that a discernible odor has been emitted. Any process
that may involve the creation or emission of any odors must be provided with a
primary and a secondary safeguard system so that control will be maintained if
the primary safeguard system fails.