Text from the PDF text layer; check the PDF for anything that matters.CHAPTER 165 ZONING REGULATIONS
of the Zoning Administrator.) Photometric plans shall be based on a
light loss factor of 1.0.
(7) Other information and data reasonably necessary to evaluate
the required lighting plan pursuant to the request of the Planning and
Zoning Commission.
4. Measuring Light Levels.
A. Metering Equipment. Light levels of both direct and indirect light
shall be measured in foot-candles with a direct reading, portable light meter.
Readings shall be taken only after the cell has been exposed long enough to
provide a constant reading.
B. Method of Measurement. Foot-candle horizontal measurements shall
be taken along a horizontal plane at a height of three and one-half feet above
the ground. Foot-candle vertical measurement shall be taken at a minimum
height of three and one half feet above the ground, but it may also be taken at
any height along a vertical plane along a property boundary line if required by
the Planning and Zoning Commission.
5. Standards and Requirements.
A. Tables 1 and 2. The standards and requirements set forth in the
following tables regulate and govern the use, design, construction, or
modification of any lighting system for the purpose of illuminating exterior
areas including, but not limited to, signs, parking areas, building, landscaping,
porches, and driveways.
(1) Table 1 sets forth whether the proposed wattage of luminaries
is permitted, or a special use. In residential zoning districts, whether
a specified wattage is permitted or not permitted is based on the width
of the street right-of-way abutting the proposed luminaries. In non-
residential zoning districts, the permitted wattage of proposed exterior
lighting is based on whether the lighting is internal or external on the
parcel, and if external (abutting a residential zoning district or street
right-of-way) the setback of the proposed lighting from the property
line or street right-of-way. Uses permitted by right may be approved
by the Planning and Zoning Commission pending a review of the
documents submitted that meet the requirements of this section. Uses
or lighting plans that require a special use permit shall meet the
requirements for special uses that provide for a public hearing held by
the Planning and Zoning Commission and approval by the Council.
Table 1
Lighting in Residential Districts Lighting in Non-Residential
Districts
Multiple Non- External - Abutting a Residential
Single Interna
Family Residential Zoning District or Street
Family l
R.O.W.
Uses
Use Use (Institutional Setback Setback Setback Setback
etc.)
CODE OF ORDINANCES, TIFFIN, IOWA