other · C
Discussion and Review of Tiffin Municipal Code Revisions – Preparation for Setting the Public Hearing — Tiffin City Code - DRAFT
Dated September 15, 2026City Council — work session, September 15, 2026 718 pages
Ord. 1983-117, Ord. 2018-437, Ord. 2010-302, Ord. 2012-309, Ord. 2007-288, Ord. 2012-313, Ord. 2007-287, Ord. 2018-433, Ord. 2019-446, Ord. 2012-319, Ord. 69
Page 393 of 718
Text from the PDF text layer; check the PDF for anything that matters.CHAPTER 160 FLOODPLAIN MANAGEMENT
a. A minimum of two (2) openings having a total net
area of not less than one (1) square inch for every square foot
of enclosed area subject to flooding shall be provided.
b. The bottom of all openings shall be no higher than
one (1) foot above grade.
c. Openings may be equipped with screens, louvers,
valves, or other coverings or devices provided they permit the
automatic entry and exit of floodwaters.
Such areas shall be used solely for parking of vehicles, building access, and
low damage potential storage.
(2) New and substantially improved structures must be designed
(or modified) and adequately anchored to prevent flotation, collapse,
or lateral movement of the structure resulting from hydrodynamic and
hydrostatic loads, including the effects of buoyancy.
(3) New and substantially improved structures shall be
constructed with electric meter, electrical service panel box, hot water
heater, heating, air conditioning, ventilation equipment (including
ductwork), and other similar machinery and equipment elevated (or in
the case of non-residential structures, optionally floodproofed to) a
minimum of one (1) foot above the Base Flood Elevation.
(4) New and substantially improved structures shall be
constructed with plumbing, gas lines, water meters, gas meters, and
other similar service utilities either elevated (or in the case of non-
residential structures, optionally floodproofed to) a minimum of one
(1) foot above the Base Flood Elevation or designed to be watertight
and withstand inundation to such a level.
E. Factory-Built Homes.
(1) All new and substantially improved factory-built homes,
including those placed in existing factory-built home parks or
subdivisions, shall be elevated on a permanent foundation such that
the lowest floor of the structure is a minimum of one (1) foot above
the Base Flood Elevation.
(2) All new and substantially improved factory-built homes,
including those placed in existing factory-built home parks or
subdivisions, shall be anchored to resist flotation, collapse, or lateral
movement. Anchorage systems may include, but are not limited to,
use of over-the-top or frame ties to ground anchors as required by the
State Building Code.
F. Utility and Sanitary Systems.
(1) On-site waste disposal and water supply systems shall be
located or designed to avoid impairment to the system or
contamination from the system during flooding.
(2) All new and replacement sanitary sewage systems shall be
designed to minimize or eliminate infiltration of flood waters into the
system as well as the discharge of effluent into flood waters.
CODE OF ORDINANCES, TIFFIN, IOWA
- 1413 -
Sources
- revize: Tiffin City Code - DRAFT (gFbbE0YR86eHDItZtXhZZqxLfknUlz.pdf) — where it was found ↗ first seen Oct 12, 2026
Attached to agenda item: C Discussion and Review of Tiffin Municipal Code Revisions – Preparation for Setting the...
Data last updated October 16, 2026. Built from the archive's documents; see how the data is built.