Text from the PDF text layer; check the PDF for anything that matters.CHAPTER 158 SUDAS
Table 4C - 1.02 Water Service Connections(1)
Number of Connections Number of Meters and
Type
and Size of Service Pipe Billing Requirements
1 meter - 1 curbstop
Single-family 1 - 1 inch
individual billing
1 meter for each unit, 2
Duplex or zero-lot line 2 - 1 inch curbstops individual
billing
All units must be plumbed
Townhouse or multiple
1 - 1 for each unit for individual meters and
side-by-side apartments
curbstops
All units must be plumbed
Multi-story apartments
1 -1 inch for each unit for individual meters and
max 6 units
curbstops
Requires City Engineer All units must be plumbed
approval. Must be sized for individual meters.
for available main Apartments or
Multi-story apartments 7
pressures and line condominiums with
units or more**
distances. May require specific by-laws may have
larger private service built single meter and billing
to City standards.
Requires City Engineer All units must be plumbed
approval. Must be sized for individual meter.
for available main Commercial and
Commercial or mixed-use
pressures and line residential users must have
development
distances. May requires separate meters and
larger private service built billing.
to City standards.
(1)
All services shall be designed to accommodate available pressures in existing water
main, distances from the main to the user, and the City’s fire protection requirements.
**
Apartment or condominiums with three habitable stories or any other structure with
nine or more dwelling units is required to provide a fire protection sprinkler system.
This system must be designed in accordance with the City’s Building Code
requirements, and be approved by the City Engineer.
H. 4C-1 N. Add the following section:
“N. Location of Easements
1. All watermains shall be located within the public right-of-way. In
rare exceptions, dedicated easements may be used for location of
watermain outside of the right-of-way.
2. The minimum easement width is 10-feet.”
5. Chapter 5 Roadway Design.
A. 5A-1 C. Add the following subsection:
“C. Permits.
State and federal permits may be required, depending on the
circumstances. It shall be the responsibility of the Project
CODE OF ORDINANCES, TIFFIN, IOWA
- 1366 -
Sources
- revize: Tiffin City Code - DRAFT (gFbbE0YR86eHDItZtXhZZqxLfknUlz.pdf) — where it was found ↗ first seen Oct 12, 2026
Attached to agenda item: C Discussion and Review of Tiffin Municipal Code Revisions – Preparation for Setting the...
Data last updated October 17, 2026. Built from the archive's documents; see how the data is built.