Text from the PDF text layer; check the PDF for anything that matters.CHAPTER 156 HOUSING CODE
(4) Where only one exit is required, it shall be a continuous and
unobstructed means of egress which discharges directly or via
corridors or stairways to a public way.
(5) Where at least two exits are required, they shall be
independent, unobstructed means of egress remote from each other,
and both shall discharge directly or via corridors or stairways or both
to a public way or yard. If both means of egress are designated to a
common corridor, they shall be in opposite directions immediately
upon exiting the dwelling unit or rooming unit, except a common path
of travel may be permitted for the first 20 feet. Dead-end corridors
shall not exceed 20 feet in length. However, any existing fire escape
shall not be deemed a sufficient means of egress unless it is in
compliance with the Fire Codes of the State and the City.
(6) Basements and floors above the second story shall have not
less than two exits, except when such floors or basements are used
exclusively for the service of the building. Dwelling units or rooming
units in a basement may have access to only one common exit when
the occupant load served by that exit does not exceed 10. Escape and
rescue windows must be supplied for each sleeping room. Such
windows shall comply with the International Building Code
specification S2. Existing third floor and attic areas less than 500
square feet may be used as habitable rooms if the following
conditions are met: (i) one exit fully meets International Building
Code requirements to the outside of the building; (ii) the other exit
can be an attic fire escape. If access to the attic fire escape is through
a window, such window must meet the International Building Code
requirements for escape and rescue windows.
(7) Every doorway providing ingress or egress from any dwelling
unit, rooming unit, or habitable room shall be at least six feet, four
inches high and two feet, four inches wide.
B. Every means of egress shall comply with the following requirements:
(1) Stairways. All stairways comprised of four or more risers
shall be provided with a substantial and safe handrail. New
construction or remodeling shall comply with the City Building Code.
(2) Guardrails. All unenclosed floor and roof openings, open and
glazed sides of landings and ramps, balconies or porches which are
more than 30 inches above grade or above the floor below and any
roof used for other than service of the building shall be protected by a
substantial and safe guardrail. New construction or remodeling shall
comply with the City Building Code.
(3) Riser and Tread. Every stairway shall have a uniform riser
height and uniform tread width which shall be adequate for safe use.
(4) Exits. Doors and windows readily accessible from outside
the unit shall be lockable from inside the unit. Double cylinder
deadbolts may not be used on doors located in habitable areas or on
any exit door. Exit doors shall be openable from the inside without
the use of a key or any special knowledge or effort.
CODE OF ORDINANCES, TIFFIN, IOWA
- 1335 -