Text from the PDF text layer; check the PDF for anything that matters.CHAPTER 155 BUILDING CODES
Manual J Design Criteria
Elevation Latitude Winter Summer Altitude Indoor Design Design Heating
Heating Cooling Correction Temperature Temperature Temperature
Factor Cooling Difference
661′ 41 -6 89 N/A 72 75 78
Cooling Wind Wind Coincident Daily Range Winter Summer
Temperature Velocity Velocity Wet Bulb Humidity Humidity
Differences Heating Cooling
14 25 10 76 M 39 gr/lb diff 53 gr/lb diff
8. Amend Section R404.1.3.2 by adding table R404.1.2.10. (see below)
Table 404.1.2.10 Minimum Vertical Reinforcement for 8-Inch-Thick Concrete
Wall
Wall Vertical Reinforcement Bar Size and
Spacing
Less than 6 feet NSR
6 feet to 8 feet #4 at 32 inches o.c.
9 feet to 10 feet #4 at 10 inches o.c. at 16 inches o.c. #6 at 22
inches o.c.
Greater than 10 feet Design Required
9. Amend Section G2406.2 (303.3), Prohibited locations of the IRC. Modify by
deleting exceptions 3 and 4.
10. Delete Chapter 11 in its entirety and insert in lieu thereof the following:
“Chapter 11 Energy Efficiency, Section N1101. Energy efficiency for the
design and construction of buildings regulated by this code shall be as
required by chapter 661-303 of the Iowa Administrative Code.”
11. Part V: Mechanical, Chapter 12 through 23: Delete Part V Mechanical,
Chapters 12 through 23 of the International Residential Code in its entirety.
Mechanical systems shall comply with the State Mechanical Code. Administrative
Provisions in Chapter 1 of this code as amended.
12. Part VII Plumbing, Chapters 25 through 33. Delete Party VII Plumbing
Chapters 25 through 33 and insert the following:
“Part VII Plumbing, Chapter 25, Section 2501 GENERAL, P2501.1 Scope.
Plumbing systems shall comply with the State Plumbing Code.
Administrative Provisions. The Plumbing Code shall be administered in
accordance with administrative provisions in Chapter 1 of this code as
amended.”
13. Part VIII Electrical: Chapters 37 through 43 inclusive of the IRC. Delete Part
VIII Electrical Chapters 34-43 inclusive of the IRC and insert the following:
“Part VIII electrical, Chapter 34. Section E3401 GENERAL. E3401.1
Applicability. Electrical systems shall comply with the State Electrical
Code.”
14. Appendix J. Section AJ102.4 of the IRC. Delete Section AJ102.4 of the IRC
and insert in lieu thereof the following:
“AJ102.4 Replacement windows and doors. Regardless of the category of
work, where an existing window or door, including the sash and glazed
CODE OF ORDINANCES, TIFFIN, IOWA
- 1306 -