original approval. Any change to the interior finish that is regulated by the provisions of this code, or the building code shall be made in accordance with all applicable requirements. SECTION 807 DECORATIVE MATERIALS AND ARTIFICIAL DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS Section 807.5.2.1 Delete exception 2. Section 807.5.5.1 Delete exception 2. CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS SECTION 901 GENERAL Section 901.2 (a) Add a new section to read as follows: Water-based fire protection systems. Working plans submitted to the fire department for water- based fire protection systems shall be stamped and approved by a qualified person to be in compliance with applicable NFPA standards and the Tiffin Fire Code. Any changes to the working plans shall be approved by a qualified person. A qualified person shall have a minimum National Institute for Certification in Engineering Technologies [NICET] Level III certification for Automatic Sprinkler System Layout OR be a licensed engineer with experience in life safety system design. Other qualifications may be approved by the Fire Code Official. Section 901.2 (b) Add a new section to read as follows: Fire alarm systems. Working plans submitted to the fire department by a qualified person for fire alarm systems shall be stamped and approved by a qualified person to be in compliance with applicable NFPA standards and the Tiffin Fire Code. Any changes to the working plans shall be approved by a qualified person. A qualified person shall have a minimum National Institute for Certification in Engineering Technologies [NICET] Level III certification for Fire Alarm Systems OR be a licensed engineer with experience in life safety system design. Other qualifications may be approved by the Fire Code Official. Section 901.4.7.1. Add a sentence to the end of the section to read as follows: The fire pump room or automatic sprinkler riser room shall have an exterior access door. The room shall have a hard-cleanable walking surface from the fire department access road. Section 901.4.7.3. Add a sentence to the end of the section to read as follows: The fire pump room or automatic sprinkler riser room shall have a supervised room temperature sensor.

Sources

  • sharepoint (G-1, H-1 - Ordinance 2025-519 - 2024 International Fire Code with Amendents.pdf) — where it was found ↗ first seen Oct 12, 2026

This document's details as JSON

Data last updated October 15, 2026. Built from the archive's documents; see how the data is built.