Text from the PDF text layer; check the PDF for anything that matters. 8. Cooking or Eating in Rooming Units. No occupant of a rooming unit shall prepare or eat
meals or store cooking utensils in the rooming unit unless an approved kitchen or dining room is
contained within the rooming unit. The cooking and eating of meals may take place in dwellings
containing a rooming unit or units if the provisions of subsections 156.18(7) and (8) of this
chapter are complied with.
9. Occupancy Control.
A. A dwelling unit shall not be occupied by a number of persons greater than
allowed by the City Zoning Ordinance.
B. No room shall be used as a habitable room unless certified as a habitable room at
the time the certificate of structure compliance is issued or amended.
10. Fire Protection Equipment. All fire extinguishers and early warning fire protection
systems shall be maintained in good working condition at all times. Fire extinguishers shall be
mounted and meet the requirements of the City Fire Code.
156.21 TITLE 24 OF THE CODE OF FEDERAL REGULATIONS; SECTION 882.109(a)
THROUGH (l); HOUSING QUALITY STANDARDS. Housing used in this program shall meet the
performance requirements set forth in this section. In addition, the housing shall meet the acceptability
criteria set forth in this section except for such variations as are proposed by the PHA and approved by
HUD. Local climatic or geological conditions or local codes are examples which may justify such
variations. The term “this program” shall be interpreted to mean the Section VIII Housing Assistance
Payments Program. Further, in accordance with the Code of Iowa, as amended, this section has provided
the basis for provisions of the Tiffin Housing Code.
1. Sanitary Facilities.
A. Performance Requirement. The dwelling unit shall include its own facilities
which are in proper operating condition, can be used in privacy, and are adequate for
personal cleanliness and the disposal of human waste.
B. Acceptability Criteria. A flush toilet in a separate, private room, a fixed basin
with hot and cold running water shall be present in the dwelling unit, all in proper
operating condition. These facilities shall utilize an approved public or private disposal
system.
2. Food Preparation and Solid Waste Disposal.
A. Performance Requirement. The dwelling unit shall contain suitable space and
equipment to store, prepare, and serve foods in a sanitary manner. There shall be
adequate facilities and services for the sanitary disposal of food wastes and solid waste,
including facilities for temporary storage where necessary.
B. Acceptability Criteria. The unit shall contain the following equipment in proper
operating condition: cooking stove or range and a refrigerator of appropriate size for the
unit, supplied by either the owner or the family, and a kitchen sink with hot and cold
running water. The sink shall drain into an approved public or private system. Adequate
space for the storage, preparation, and serving of food shall be provided. There shall be
adequate facilities and services for the sanitary disposal of food wastes and solid waste,
including facilities for temporary storage where necessary, e.g., garbage cans.
3. Space and Security.
A. Performance Requirement. The dwelling unit shall afford the family adequate
space and security.