direction of the Engineer, if other testing fails. Costs associated with video inspection shall be incidental to the Cleaning, Inspection, and Acceptance Testing item. Division 5 – Water mains and Appurtenances Section 5010 Water mains and Appurtenances Article 1.08 C Make the following changes to Article 1.08 C 1.08 C. 1.a. Measurement Each Fitting(tee, bend, reducer, sleeve, cap, etc.) installed as specified on the plans, Contract Documents, or as required for proper installation of the water main will be counted regardless of size. 1.08 C. 1. b. Payment Payment will be made at the contract unit price for each fitting installed. Article 2.03Add the following statement Preferences will be made for domestically made products and materials. Article 2.07 C Add the following Jurisdictional Requirements 2.07 C. Corporations, Stops, and Stop Boxes Corpstop shall be A.Y. McDonald #4701, #4701B, or approved equal. Curbstops shall be A.Y. McDonald #6100, or approved equal. Stop boxes shall be A.Y. MCDONALD #5607L with stainless steel operating rod, or approved equal. Stop box cap shall have removable brass access plug. Preferences will be made for domestically made products and materials. Article 3.06 H. Add the following Jurisdictional Requirements H. The above tracer wire system requirements shall also apply to water service piping. Tracer wire shall be installed with the service piping from the water main to the building that is being served. Tracer ware shall be tied into the tracer wire system of the watermain. Section 5020 Valves, Fire Hydrants, and Appurtenances Article 1.08 Make the following changes 1.08 A. Valve (Butterfly or Gate) 1.08 A.3 Includes: Unit price also includes furnishing all labor, materials, and equipment necessary to install Valves Box Adaptor II, manufactured by Adaptor Inc., or approved equal, with all proposed valve boxes. 1.08 B. Tapping Valve Assembly 1.08 B.3 Includes: Unit price also includes furnishing all labor, materials, and equipment necessary to install Valves Box Adaptor II, manufactured by Adaptor Inc., or approved equal, with the valve box. 1.08 C. Fire Hydrant Assembly 1.08 C.3 Includes: Unit price also includes furnishing all labor, materials, and equipment necessary to install Valves Box Adaptor II, manufactured by Adaptor Inc., or approved equal, with the valve box. 1.08 G. Valve Box Replacement 1.08 G.3 Includes: Unit price also includes furnishing all labor, materials, and equipment necessary to install Valves Box Adaptor II, manufactured by Adaptor Inc., or approved equal, with all replaced valve boxes. Article 2.01 B. 4. Add the following article 20

Sources

  • citycode: 2019 Design Standards Amendments (2019-Design-Standards-Amendments.pdf) — where it was found ↗ first seen Oct 12, 2026

This document's details as JSON

Data last updated October 16, 2026. Built from the archive's documents; see how the data is built.