Text read by the vision model; check the PDF for anything that matters.
CHAPTER 5 - FIRE SERVICE FEATURES SECTION 505 PREMISES IDENTIFICATION Section 505.1 Add table. Minimum Height and Stroke Width a,b,c,d <table> <tr> <th>Distance from the centerline of the Public Way (ft)</th> <th>Minimum Height (in)</th> <th>Minimum Stroke Width (in)</th> </tr> <tr> <td>Less than 100</td> <td>6</td> <td>3/4</td> </tr> <tr> <td>100</td> <td>199</td> <td>8</td> <td>1</td> </tr> <tr> <td>200</td> <td>299</td> <td>10</td> <td>1 1/4</td> </tr> <tr> <td>For each additional 100</td> <td>Increase 2</td> <td>Increase 1/2</td> </tr> </table> a. Exterior suite identification, minimum height shall be 4 inches and stroke width shall be 1/2 inch. b. Interior suite identification, minimum height shall be 3 inches and stroke width shall be 1/4 inch. c. Measurements to determine the minimum number or letter size shall be measured from the approved address location to the center line of the street for which the premise is addressed. d. Minimum height and minimum stroke may be increased by the Fire Code Official. (Change: Increase for minimum size of address numbers by 2 inches and stroke respectively to increase visibility for emergency responders. Previous Amendment; Less than 100 Feet: 4"x1/2" stroke, 100-199 Feet: 6"x 3/4" stroke and 200-299 Feet: 8" x 1" stroke. Section 505.3 Add a new section to read as follows: Addresses for Buildings under Construction. Upon permit issuance, all new commercial and residential buildings under construction shall have plainly visible addresses from the street. Additional address signage may be required at the discretion of the Fire Code Official. Section 505.4 Add a new section to read as follows: Addresses for Buildings Additional address signage may be required at the discretion of the Fire Code Official. This allows for additional address signage to be placed on structures with multiple entrance or suite numbers to be placed on the front and rear door. This is at the discretion of the Fire Code Official. SECTION 506 KEY BOXES Section 506.1 Add a sentence to the end of the section to read as follows: City of Tiffin Municipal Code.

Sources

  • laserfiche: Ordinances-2025-519 (Ordinances-2025-519.pdf) — where it was found ↗ first seen Oct 12, 2026

This document's details as JSON

Data last updated October 15, 2026. Built from the archive's documents; see how the data is built.