SECTION 907 FIRE ALARM AND DETECTION SYSTEMS Section 906.3 Add a sentence to the end of the section to read as follows: The minimum size and rating of any required portable fire extinguisher for Class A, Class B, or Class C hazard shall be 5lb. 2-A, 10-B C. Section 907.1.4 Add a new section to read as follows: Fire alarm control panels and Fire alarm annunciator panels. Installation of fire alarm control panels and fire alarm annunciator panels shall be installed in accordance with section 907.1.4.1 through 907.1.4.5. Section 907.1.4.1 Add a new section to read as follows: Fire Alarm Panel Height: Installation of fire alarm panels shall not exceed 6 feet in height measured from the floor to the top of the panel. Exception: Panel height may be altered by the Fire Code Official. Section 907.1.4.2 Add a new section to read as follows: Number of Fire Alarm Control Panels in Buildings: Only one listed fire alarm control panel shall be allowed per building and shall lock in the alarm until the system is reset and shall not be canceled by the operation of an audible – alarm silencing switch. This control panel shall only receive alarm signals from fire protection equipment. Section 907.1.4.3 Add a new section to read as follows: Combination Fire/Security Alarm System Panels. A listed combination fire/security alarm system panel that meets all the requirements of this code and amendments may be permitted by approval of the Fire Code Official. The fire/security panel shall be capable of providing a signal that can differentiate between the fire and security alarm. Section 907.1.4.4 Add a new section to read as follows: Password/PIN Protection Prohibited: Fire alarm control panels and/or fire alarm annunciator panels that require a password/PIN to silence an alarm/supervisory/trouble signal and/or to reset an alarm/supervisory/trouble signal shall be prohibited. Section 907.1.4.5 Add a new section to read as follows: Fire Alarm Annunciator Panels: The Fire Code Official can require addition fire alarm annunciator panels based on the size of building and access to the building, these panels shall meet the requirements of 907.1.4 and 907.2. Section 907.2 Delete the section and replace it with: Where required new buildings and structures. An approved and addressable manual, automatic or manual and automatic fire alarm system installed in accordance with the provisions of this code and NFPA 72 shall be provided in new buildings and structures in accordance with Sections 907.2.1 through 907.2.23 and provide occupant notification in accordance with 907.5 unless other requirements are provided by another section of this code. Not fewer than one manual fire alarm box shall be provided in an approved location to initiate a fire alarm signal for

Sources

  • laserfiche: Ordinances-2025-519 (Ordinances-2025-519.pdf) — where it was found ↗ first seen Oct 12, 2026

This document's details as JSON

Data last updated October 15, 2026. Built from the archive's documents; see how the data is built.