Exception: Receptacles not readily accessible and supplied by a dedicated branch circuit for electric snow-melting or deicing equipment shall be permitted to be installed in accordance with 426.28. (4) Crawl spaces at or below grade level. (5) Unfinished basements, for the purposes of this section, unfinished basements are defined as portions or areas of the basement not intended as habitable rooms and limited tom storage areas, work areas, and other similar uses. Exceptions: 1. Receptacles not readily accessible. 2. A single receptacle or a duplex receptacle for two appliances located within dedicated space for each appliance that, in normal use, is not easily moved from one place to another and that is cord-and-plug connected in accordance with 400.7(A)(6), (A)(7), or (A)(8). 3. A receptacle supplying a permanently installed fire or burglar alarm systems. Receptacles installed under exception 210.8(A) (2) shall not be considered as meeting the requirements of 210.52(G). (6) Kitchen receptacles that serve a countertop surface. (7) Laundry, utility, and wet bar sink receptacles when installed within 6-ft of outside edge of a sink. 2702.1 Installation. Emergency and standby power systems shall be installed in accordance with the 2011 National Electrical Code, NFPA 110, and NFPA 111. 6. Delete the following Section from Chapter Thirty-four of the IBC and insert in lieu thereof the following: 3410.2 Applicability. Structures existing prior to the effective date of this ordinance and in which there is work involving additions, alterations or changes of occupancy shall be made to conform to the requirements of this section or the provisions of Sections 3403 through 3407. The provisions in Sections 3410.2.1 through 3410.2.5 shall apply to existing occupancies that will continue to be, or are proposed to be, in Groups A, B, E, F, M, R, S and U. These provisions shall not apply to buildings with occupancies in Group H or I. 7. Delete the following Sections from Chapter One of the IRC and insert in lieu thereof the following: R101.1 Title. These provisions shall be known as the Residential Code for One- and Two-Family Dwellings of Tiffin, and shall be cited as such and will be referred to herein as "this code". R105.1 Required. Any owner or authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical or plumbing system, the installation of which is regulated by this code, or to cause any such work to be done, shall first make application to the building official and obtain the required permit. R105.1.1 Issuance of permits.

Sources

  • laserfiche: Ordinances-2013-322 (Ordinances-2013-322.pdf) — where it was found ↗ first seen Oct 12, 2026

This document's details as JSON

Data last updated October 15, 2026. Built from the archive's documents; see how the data is built.