ordinance

Ordinances-2013-322

Dated February 28, 2013 16 pages Ord. 2013-322, Ord. 322

Open the PDF

Page 10 of 16

Text read by the vision model; check the PDF for anything that matters.
Buildings shall be constructed in accordance with the provisions of this code as limited by the provisions of this section. Additional criteria shall be established by the local jurisdiction and set forth in Table R301.2 (1). Table R301.2(1) Climatic and Geographic Design Criteria <table> <tr> <th rowspan="2">Ground Snow Load</th> <th rowspan="2">Wind Speed MPH</th> <th rowspan="2">Seismic Design Category</th> <th colspan="6">Subject To Damage From</th> <th rowspan="2">Air Freezing Index</th> <th rowspan="2">Mean Annual Temp</th> </tr> <tr> <th>Frost Line Depth</th> <th>Weathering</th> <th>Termite</th> <th>Winter Design Temp</th> <th>Ice Shield Under-layment Required</th> <th>Flood Hazards</th> </tr> <tr> <td>25</td> <td>90</td> <td>A</td> <td>42"</td> <td>Severe</td> <td>M - H</td> <td>S - M</td> <td>-5° F</td> <td>Yes</td> <td>8/22/02</td> <td>2000</td> <td>50 F</td> </tr> </table> R302.2 Townhouses. Each townhouse shall be considered a separate building and shall be separated by fire-resistance-rated wall assemblies meeting the requirements of Section R302 for exterior walls. Exception: A common 2-hour fire-resistance-rated wall is permitted for townhouses if such walls do not contain plumbing or mechanical equipment, ducts or vents in the cavity of the common wall. Electrical installations shall be installed in accordance with Chapters 33 through 42. Penetrations of electrical outlet boxes shall be in accordance with Section R302.3. R302.2.1 Continuity. The fire-resistance-rated wall or assembly separating townhouses shall be continuous from the foundation to the underside of the roof sheathing, deck or slab. The fire-resistance rating shall extend the full length of the wall or assembly, including wall extensions through and separating attached enclosed accessory structures. R302.2.2 Parapets. Parapets constructed in accordance with Section R302.2.3 shall be constructed for townhouses as an extension of exterior walls or common walls in accordance with the following: 1. Where roof surfaces adjacent to the wall or walls are at the same elevation, the parapet shall extend not less than 30 inches (762 mm) above the roof surfaces. 2. Where roof surfaces adjacent to the wall or walls are at different elevations and the higher roof is not more than 30 inches (762 mm) above the lower roof, the parapet shall extend not less than 30 inches (762 mm) above the lower roof surface. Exception: A parapet is not required in the two cases above when the roof is covered with a minimum class C roof covering, and the roof decking or sheathing is of noncombustible materials or approved fire-retardant treated wood for a distance of 4 feet (1219 mm) on each side of the wall or walls, or one layer of 5/8-inch (15.9 mm) Type X gypsum board is installed directly beneath the roof decking or sheathing, supported by a minimum of nominal 2-inch (51 mm) ledgers attached to the sides of the roof framing members, for a minimum distance of 4 feet (1220 mm) on each side of the wall or walls. 3. A parapet is not required where roof surfaces adjacent to the wall or walls are at different elevations and the higher roof is more than 30 inches (762 mm) above the lower roof. The common wall construction from the lower roof to the underside of the higher roof deck shall have not less than a 1-hour fire-resistance rating. The wall shall be rated for exposure from both sides.

Sources

  • laserfiche: Ordinances-2013-322 (Ordinances-2013-322.pdf) — where it was found ↗ first seen Oct 12, 2026

This document's details as JSON

Data last updated October 16, 2026. Built from the archive's documents; see how the data is built.