Electrical Requirements Treadmills: Most AC-110V commercial treadmills require the use of a 100-125vac, 50-60Hz. 20amp dedicated circuit )2.5KW maximum). The outlet should be a NEMA 5-20R. The hot, neutral, and ground must all be independently isolated (not looped or tied to other circuits). Bikes, Ellipticals & Steppers: Most commercial bikes and ellipticals can be self- powered. A minimum RPM is needed to maintain power to the bikes and ellipticals. Some manufacturers offer optional 110 standard power cord due to the delay of up to 30 seconds needed for the console to load prior to the user starting a program. If a power is used, up to 4 units can be daisy chained together on a 20amp circuit using a daisy chain cord adaptor (sold separately). They will power the unit at all times and does not require a minimum RPM for use. NEMA Outlet 120VAC, 20AMP 60 Hz NEMA 5-20R