Text from the PDF text layer; check the PDF for anything that matters.CHAPTER 166 ESTABLISHMENT OF ZONING DISTRICTS AND THE OFFICIAL ZONING MAP
p.m. Such activities are those that are non-routine
operations accessory to the primary activities and that
are temporary in nature, or conducted infrequently.
iii. Transient vibrations of moving sources such
as automobiles, trucks, airplanes, and railroads.
(3) Smoke and Particulate Matter. Any emission from a lot of
particulate matter containing more than five percent by weight of
particles having a particle diameter larger than 44 microns is
prohibited. Dust and other types of air pollution borne by the wind
from such sources as storage areas, yards, and roads within the
boundaries of any lot must be kept to a minimum by appropriate
landscaping, paving, oiling, or other acceptable means. Emission of
particulate matter from such sources in excess of the weight
limitations specified herein is prohibited. The emission of smoke or
particulate matter of a density or equivalent opacity equal to, or
greater than, Ringelmann Chart No. 2 is prohibited at all times, except
as otherwise provided herein. (The Ringelmann Chart is the chart
published by the United States Bureau of Mines).
a. Smoke Emission. In the M-2 District, the emission
of more than 12 smoke units per stack in any one-hour
period is prohibited. However, once during any six-hour
period each stack may be permitted up to 12 additional units
in a 15-minute period for soot blowing and fire cleaning.
Only during such 15 minute periods may smoke of a density
or equivalent opacity equal to, but not exceeding,
Ringelmann Chart No. 3 be permitted, and then only for fire
cleaning and for not more than four minutes per period.
b. Particulate Matter. The rate of emission particulate
matter from all sources within the boundaries of any lot shall
not exceed the rate established in the following table:
Maximum Permitted Particulate Matter Emission Rate
Height of Emission Pounds Per Hour
(ft) (per acre)
0-49 1.00
50-99 1.01
100-149 1.06
150-199 1.10
200-299 1.16
300-399 1.30
400-over 1.50
c. Method of Measurement.
i. Smoke. To grade the density or equivalent
opacity of emission of smoke, the Ringelmann Chart
shall be used. To determine smoke units, the
Ringelmann reading shall be made at least every
minute during the period of observation. Each
reading (Ringelmann number) shall be multiplied by
CODE OF ORDINANCES, TIFFIN, IOWA