staff report memo · E-8

Approval of State Revolving Fund (SRF) Reimbursement Request #9 - Water Treatment Facility Upgrade Project — E-8

Open the PDF Searchable (OCR) PDF

Page 10 of 14

Text read by the vision model; check the PDF for anything that matters.
<table> <tr> <th>Application No.: 13</th> <th>Application Period:</th> <th>From</th> <th>08/22/26</th> <th>to</th> <th>09/24/26</th> <th>Application Date:</th> <th>09/25/26</th> </tr> <tr> <td>180</td> <td>Bldg 10 - Foundations (Exc&BF)</td> <td>$25,630.00</td> <td>25,630.00</td> <td></td> <td></td> <td>25,630.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>181</td> <td>Bldg 20 - RO Fundations (Exc&BF)</td> <td>$45,250.00</td> <td>45,250.00</td> <td></td> <td></td> <td>45,250.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>182</td> <td>Bldg 20 - Aeration Tank Found (Ex&BF)</td> <td>$15,640.00</td> <td>15,640.00</td> <td></td> <td></td> <td>15,640.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>183</td> <td>Bldg 30 - Foundations (Exc&BF)</td> <td>$37,650.00</td> <td>35,767.50</td> <td></td> <td></td> <td>35,767.50</td> <td>95%</td> <td>1,882.50</td> </tr> <tr> <td>184</td> <td></td> <td></td> <td>-</td> <td></td> <td></td> <td>-</td> <td>-</td> <td>-</td> </tr> <tr> <td>185</td> <td><b>Exterior Improvements</b></td> <td></td> <td>-</td> <td></td> <td></td> <td>-</td> <td>-</td> <td>-</td> </tr> <tr> <td>186</td> <td>Asphalt Paving (Trail)</td> <td>$22,130.00</td> <td>22,130.00</td> <td></td> <td></td> <td>22,130.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>187</td> <td>Concrete Paving (Site)</td> <td>$130,288.00</td> <td>97,716.00</td> <td></td> <td></td> <td>97,716.00</td> <td>75%</td> <td>32,572.00</td> </tr> <tr> <td>188</td> <td>Chain Link Fencing</td> <td>$32,250.00</td> <td>-</td> <td></td> <td></td> <td>-</td> <td>0%</td> <td>32,250.00</td> </tr> <tr> <td>189</td> <td>Seeding</td> <td>$6,914.00</td> <td>-</td> <td></td> <td></td> <td>-</td> <td>0%</td> <td>6,914.00</td> </tr> <tr> <td>190</td> <td></td> <td></td> <td>-</td> <td></td> <td></td> <td>-</td> <td>-</td> <td>-</td> </tr> <tr> <td>191</td> <td><b>Utilities</b></td> <td></td> <td>-</td> <td></td> <td></td> <td>-</td> <td>-</td> <td>-</td> </tr> <tr> <td>192</td> <td>A - 12" W to Clearwell</td> <td>$32,544.00</td> <td>29,289.60</td> <td>3,254.40</td> <td></td> <td>32,544.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>193</td> <td>B - 8" W to Clearwell</td> <td>$25,663.00</td> <td>25,663.00</td> <td></td> <td></td> <td>25,663.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>194</td> <td>C - UG Storm Sewer North</td> <td>$48,686.00</td> <td>38,948.80</td> <td></td> <td></td> <td>38,948.80</td> <td>80%</td> <td>9,737.20</td> </tr> <tr> <td>195</td> <td>D - 12" W Aerator to Clearwell</td> <td>$18,549.00</td> <td>18,549.00</td> <td></td> <td></td> <td>18,549.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>196</td> <td>E - 12" W Bldg 10 to Bldg 20</td> <td>$8,554.00</td> <td>7,698.60</td> <td>855.40</td> <td></td> <td>8,554.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>197</td> <td>G - UG Storm Sewer East</td> <td>$67,822.00</td> <td>67,822.00</td> <td></td> <td></td> <td>67,822.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>198</td> <td>H & J - UG Storm Sewer West/South</td> <td>$87,552.00</td> <td>87,552.00</td> <td></td> <td></td> <td>87,552.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>199</td> <td>K - UG Storm Sewer Clearwell West</td> <td>$42,500.00</td> <td>-</td> <td>42,500.00</td> <td></td> <td>42,500.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>200</td> <td>F - UG Sanitary Manholes & Piping</td> <td>$165,835.00</td> <td>165,835.00</td> <td></td> <td></td> <td>165,835.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>201</td> <td>Roof Drains</td> <td>$2,500.00</td> <td>2,500.00</td> <td></td> <td></td> <td>2,500.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>202</td> <td>Bldg 20 - Process Drain Manhole</td> <td>$8,500.00</td> <td>8,500.00</td> <td></td> <td></td> <td>8,500.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>203</td> <td></td> <td></td> <td>-</td> <td></td> <td></td> <td>-</td> <td>-</td> <td>-</td> </tr> <tr> <td>204</td> <td><b>Process Integration (Piping)</b></td> <td></td> <td>-</td> <td></td> <td></td> <td>-</td> <td>-</td> <td>-</td> </tr> <tr> <td>205</td> <td><b>Structure 10 - Existing Bldg</b></td> <td></td> <td>-</td> <td></td> <td></td> <td>-</td> <td>-</td> <td>-</td> </tr> <tr> <td>206</td> <td>Process Piping Materials</td> <td>$55,103.74</td> <td>2,692.00</td> <td>15,053.00</td> <td>17,745.00</td> <td>32%</td> <td>37,358.74</td> </tr> <tr> <td>207</td> <td>Process Piping Labor</td> <td>$37,550.00</td> <td>12,016.00</td> <td></td> <td>12,016.00</td> <td>32%</td> <td>25,534.00</td> </tr> <tr> <td>208</td> <td>Valves Materials</td> <td>$9,500.00</td> <td>9,500.00</td> <td></td> <td>9,500.00</td> <td>100%</td> <td>-</td> </tr> <tr> <td>209</td> <td>Valves Labor</td> <td>$8,250.28</td> <td>1,650.06</td> <td></td> <td>1,650.06</td> <td>20%</td> <td>6,600.22</td> </tr> <tr> <td>210</td> <td><b>Structure 20 - RO Building</b></td> <td></td> <td>-</td> <td></td> <td></td> <td>-</td> <td>-</td> <td>-</td> </tr> </table>

Sources

Attached to agenda item: E-8 Approval of State Revolving Fund (SRF) Reimbursement Request #9 - Water Treatment...

This document's details as JSON

Data last updated October 15, 2026. Built from the archive's documents; see how the data is built.