other
WS - C - Concept Design - Programming Summary
Page 2 of 3
Text from the PDF text layer; check the PDF for anything that matters.TRANSITION
Air Lock Vestibules 2 100 200 0 (2) air lock vestibules with pressure control between Cool (Green) Zones and Hot (Red) Zones - Included in training stair and overall gross square footage
SUBTOTAL - TRANSITION 200 0
DECONTAMINATION
Gross - Turnout Gear Storage 1 400 400 288 (30) 2 x 2 gear grid lockers - portable vs wall-mounted (OFOI), gear dryer (OFOI), consider lockable storage for personal items - isolate from Apparatus Bay
Gross - Dirty Room 1 200 200 240 Utility sinks, extractor, mop sink, mop storage, utility shelving, gross decon shower with UV lights
Gross - Dirty Restroom 1 64 64 96 Toilet, sink
Medium - Clean Restroom 1 72 72 96 Toilet, sink, large shower with seat and shelves, lockers or cubbies - Could be pressurized air lock transition space
Medium - Clean Room 1 96 96 240 Ice machine, washer (OFOI) - res vs com, dryer (OFOI) - res vs com, utility sink, utiility shelves - Could be pressurized air lock transition space
Medium - Sauna 0 64 0 0 Assume not required
SUBTOTAL - DECONTAMINATION 832 960
OPERATIONS SUPPORT
Air Room (SCBA Fill and Storage) 1 96 100 128 Self-Contained Breathing Apparatus (SCBA) storage with air bottle racks, cascade filling station, air compressor
Workshop 1 200 200 256 Workbench, portable tool cabinet (OFOI), portable cart (OFOI), final size to be determined
Medical Room (EMS Supply Storage) 1 96 100 128 Lockable cabinet in room for secure storage
Storage 1 240 240 320 Separate storage for yard equipment, exterior access is ideal, air quality is critical - Consider secure storage options
Locker Room 0 500 0 0 Not included
Training Mezzanine 1 640 800 896 Built-in training props - removable guardrails, situation room, access panels, ladder raise - Adjacencies: Separate from living quarters due to noise
Training Stair and Hose Tower 1 300 400 672 Hose drying, designed for training with removable panels in landings, exterior is accessible by fire trucks, could serve as egress stair
SUBTOTAL - OPERATIONS SUPPORT 1,840 2,400
APPARATUS BAY
Double-Deep Bay 7 1440 10,080 10,080 Two-story, drive through, 18' x 80' bay size, 14' x 14' overhead doors with vision glass - provide power drops and air lines
Utility Alcove(s) and Equipment 0 192 Alcoves or wall space for mop sinks, mop storage, utility sinks, hand washing sinks, portable hose storage racks (OFOI), hose reels, maps, radios
Circulation 320
Vehicle Exhaust Confirm if building system similar to Plymovent - under carriage track, under carriage rail, vertical stack rail, magnetic grabber, pneumatic grabber - OR vehicle system similar to Ward
Diesel No Smoke installed in tail pipes
SUBTOTAL - APPARATUS BAY 10,080 10,592
JOHNSON COUNTY AMBULANCE
Ambulance Bay 1 1440 1,440 1,440 One, two-story, double-deep, 18' x 80' drive through bays, assuming 14' x 14', glass in doors is ok
Living Room 1 400 400 576 With kitchenette, like studio apartment, no bedrooms, no reception, assumed to be 20' x 20'
SUBTOTAL - JOHNSON COUNTY AMBULANCE 1,840 2,016
UNASSIGNED
Outdoor Car Port 1 0 Carport, quantities to be detemrined, with canopies, consider solar panels on canopies
Outdoor Space 1 0 Good size outdoor space for grilling, at grade or rooftop, adjacent to day room spaces - Size per final design
0
Agent Storage Building 0 Could be detached single-story building, located along apparatus drive leading into apparatus bay
Outdoor Training Building 0 High rise training, separate structure, roof simulator, wrecked cars
Utility Enclosure 0 If required
Generator 0 Utilize existing generator
SUBTOTAL - UNASSIGNED 0 0