Chapter 156: Housing Code

§ 156.17 Minimum Structure Standards For All Dwellings

The text in force on May 21, 2019, and every version since 2010.

Unofficial compilation built from the City's published 2010 Code chapters and the text of adopted ordinances. Effective dates are inferred from adoption records; scanned chapters were OCR'd. The City of Tiffin's adopted Code of Ordinances governs. Not legal advice.

Back to today

156.17 MINIMUM STRUCTURE STANDARDS FOR ALL DWELLINGS

1. Safety of Supplied Facility. Every supplied facility, piece of equipment, or required utility shall be constructed and/or installed so that it will function safely.

2. Kitchens. Every dwelling unit shall have a kitchen room or kitchenette equipped with the following:

A. An approved kitchen sink.

B. Space capable of properly accommodating a refrigerator and a stove or range.

C. Proper access terminals to utilities necessary to properly operate a refrigerator and stove or range.

D. Adequate space for the storage and preparation of food.

3. Toilets, Baths and Lavatories.

A. Every dwelling unit shall contain the following:

(1) A toilet.

(2) A bath.

(3) A lavatory basin within or adjacent to the room containing the toilet.

B. Every toilet and every bath shall be contained within a room or within separate rooms which afford privacy for a person within said rooms.

4. Water-Heating Facilities. Every kitchen sink, bath, and lavatory basin required in accordance with the provisions of the Housing Code shall be properly connected with supplied water-heating facilities. Every supplied water-heating facility shall be properly connected and shall be capable of heating water to such a temperature as to permit an adequate amount of water to be drawn at every kitchen sink and lavatory basin required under the provisions of the Housing Code at a temperature of not less than 120 degrees Fahrenheit. Such supplied water-heating facilities shall be capable of meeting the requirements of this section when the required space heating facilities are not in operation.

5. Connection of Sanitary Facilities to Water and Sanitary Sewer Systems. Every kitchen sink, toilet, lavatory basin, bath, and clothes washer shall be properly connected to an approved water and sanitary sewer system.

6. Exits.

A. Every structure containing a dwelling unit or dwelling units or structure containing a rooming unit or rooming units or a combination thereof shall comply with the following exit requirements:

(1) Every structure or usable portion thereof shall have at least one exit.

(2) Single-family and duplex structures over 3,000 square feet in gross floor area shall have access to two exits.

(3) Multiple dwellings and rooming houses with an occupant load of ten or more shall have access to two exits.

(4) Where only one exit is required, it shall be a continuous and unobstructed means of egress which discharges directly or via corridors or stairways to a public way.

(5) Where at least two exits are required, they shall be independent, unobstructed means of egress remote from each other, and both shall discharge directly or via corridors or stairways or both to a public way or yard. If both means of egress are designated to a common corridor, they shall be in opposite directions immediately upon exiting the dwelling unit or rooming unit, except a common path of travel may be permitted for the first 20 feet. Dead-end corridors shall not exceed 20 feet in length. However, any existing fire escape shall not be deemed a sufficient means of egress unless it is in compliance with the Fire Codes of the State and the City.

(6) Basements and floors above the second story shall have not less than two exits, except when such floors or basements are used exclusively for the service of the building. Dwelling units and/or rooming units in a basement may have access to only one common exit when the occupant load served by that exit does not exceed ten. Escape and rescue windows must be supplied for each sleeping room. Such windows shall comply with the Uniform Building Code specification S2. Existing third floor and attic areas less than 500 square feet may be used as habitable rooms if the following conditions are met: (i) one exit fully meets Uniform Building Code requirements to the outside of the building; (ii) the other exit can be an attic fire escape. If access to the attic fire escape is through a window, such window must meet the Uniform Building Code requirements for escape and rescue windows.

(7) Every doorway providing ingress or egress from any dwelling unit, rooming unit, or habitable room shall be at least six feet, four inches high and two feet, four inches wide.

B. Every means of egress shall comply with the following requirements:

(1) Stairways. All stairways comprised of four or more risers shall be provided with a substantial and safe handrail. New construction or remodeling shall comply with the City Building Code.

(2) Guardrails. All unenclosed floor and roof openings, open and glazed sides of landings and ramps, balconies or porches which are more than 30 inches above grade or above the floor below and any roof used for other than service of the building shall be protected by a substantial and safe guardrail. New construction or remodeling shall comply with the City Building Code.

(3) Riser and Tread. Every stairway shall have a uniform riser height and uniform tread width which shall be adequate for safe use.

(4) Exits. Doors and windows readily accessible from outside the unit shall be lockable from inside the unit. Double cylinder deadbolts may not be used on doors located in habitable areas or on any exit door. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort.

(5) Escape Window. In basement units where one means of egress is a window, such window shall have an unobstructed opening no less in area than that required in the Building and/or Fire Codes.

(6) Fire Escapes. No existing fire escape shall be deemed a sufficient means of egress unless it is in compliance with the Fire Codes of the State and the City.

(7) Doorways. Every doorway providing ingress or egress from any dwelling unit, rooming unit or habitable room shall be at least six feet, four inches high and 24 inches wide.

7. Natural Light.

A. Every habitable room, except a kitchen, shall have at least one window or skylight facing directly to the outdoors. The minimum total glazed window or skylight area, for every habitable room, except the kitchen, shall be at least eight percent of the floor area of such room.

B. For the purpose of determining natural light and natural ventilation requirements, any room may be considered as a portion of an adjoining room when one-half of the area of the common wall is open and unobstructed and provides an opening of not less than one-tenth of the floor area of the interior room or 25 square feet, whichever is greater.

8. Ventilation.

A. Interior Air Quality. Every dwelling unit and rooming unit shall be free from dangerous levels of air pollution from carbon monoxide, sanitary sewer gas, fuel gas, dust, and other harmful air pollutants.

B. Natural Ventilation.

(1) Every window or other device with openings to the outdoor space, used for ventilation, shall be supplied with screens of not less than 16 mesh per inch.

(2) The total openable window area, as measured between stops, in every habitable room shall be equal to at least four percent of the floor area of such room.

(3) Every door opening directly from a dwelling unit or rooming unit to outdoor space, the use of which is necessary to meet the minimum ventilation requirements of this Code, shall have a supplied screen or screens and a self-closing device.

(4) Every cellar window, soffit or roof vent used or intended to be used for ventilation and every other opening to a cellar, crawl space, or interior roof area which might provide an entry for rodents or birds shall be supplied with a heavy wire screen of not larger than one-fourth inch mesh or such device as will effectively prevent entrance.

(5) For natural ventilation, every bathroom or toilet compartment shall have at least one openable window facing directly to the outdoors and at least 45 percent of the window must be openable.

C. Mechanical Ventilation.

(1) In lieu of openable windows for natural ventilation, adequate ventilation may be a system of mechanical ventilation which provides not less than two air changes per hour in all habitable rooms and/or bathrooms or toilet compartments.

(2) No mechanical exhaust system exhausting vapors, gases, or odors shall be discharged into an attic, crawl space, or cellar unless such attic, crawl space, or cellar is adequately vented to the outside.

(3) Any kitchen or kitchenette lacking natural ventilation shall be equipped with a system of mechanical ventilation which provides at least two air changes per hour in said room. The system shall exhaust and discharge directly to outside air.

9. Heating.

A. Every dwelling shall have heating facilities which are properly installed and are capable of safely and adequately heating all habitable rooms, bathrooms, and toilet rooms located therein to a temperature of at least 68 degrees Fahrenheit and shall be capable of maintaining in all said locations a minimum temperature of 65 degrees Fahrenheit at a distance of three feet above the floor level at all times. Such heating facilities shall be so designed and equipped that heat, as herein specified, is available for all dwelling units and rooming units.

B. Every central heating unit, space heater, water heater, and cooking appliance shall be located and installed in such a manner so as to afford reasonable protection against involvement of egress facilities or egress routes in the event of uncontrolled fire in the structure.

C. Every fuel burning heating unit or water heater shall be effectively vented in a safe manner to a chimney or duct leading to the exterior of the building. The chimney, duct, and vent shall be of such design as to assure proper draft and shall be adequately supported.

D. No fuel burning furnace shall be located within any sleeping room or bathroom unless provided with adequate ducting for air supply from the exterior, and the combustion chamber for such heating unit shall be sealed from the room in an airtight manner. Fuel burning water heaters are prohibited in bathrooms and sleeping rooms.

E. Every steam or hot water boiler and every water heater shall be protected against overheating by appropriate pressure and temperature limit controls. Such controls shall have a properly installed extension pipe on the pressure temperature control valve.

F. Every fuel burning space heating unit and water heater shall be equipped with an electronic ignition or with a pilot light and an automatic control to interrupt the flow of fuel to the unit in the event of a failure of the ignition device. All such heating units shall have a limit control to prevent overheating.

10. Electrical Requirements.

A. Every habitable room shall contain at least two separate floor-or wall-type electric double convenience outlets which shall be situated a distance apart equivalent to at least 25 percent of the perimeter of the room. Every such outlet and fixture shall be properly installed.

B. Every habitable room, toilet room, bathroom, laundry room, furnace room, basement, and cellar shall contain at least one supplied ceiling-or wall-type electric light fixture or switched outlet. Every such outlet and fixture shall be properly installed.

C. Temporary wiring or extension cords shall not be used as permanent wiring.

11. Minimum Space, Use and Location Requirements.

A. Floor Area Per Occupant:

(1) Every dwelling unit shall contain at least 120 square feet of habitable floor space for the first occupant thereof and at least 100 additional square feet of habitable floor space for every additional occupant thereof.

(2) For the purpose of determining the maximum permissible occupancy, the floor area of that part of a room where the ceiling height is less than five feet shall not be considered when computing the total floor area of the room.

B. Maximum Occupancy. Not more than one family, plus that number of roomers permitted in the Zoning Ordinance, except for guests, shall occupy a dwelling unit unless a rental permit for a rooming house has been granted.

C. Sleeping Rooms. In every dwelling unit of two or more rooms and every rooming unit, every room occupied for sleeping purposes by one occupant shall contain at least 70 square feet of floor space, and every room occupied for sleeping purposes by more than one occupant shall contain at least 40 square feet of floor space for each additional occupant thereof, except two-bedroom manufactured housing shall be required to have only one bedroom in compliance with this section.

D. Ceiling Height. The ceiling height of every habitable room shall be at least seven feet.

(1) In any habitable room where the ceiling is a part of a sloping roof, at least one-half of the floor area shall have a ceiling height of at least seven feet. Floor area, as stated above, means the area of the floor where the vertical measurement from floor to ceiling is five feet or more.

(2) Obstructions of space by such items as water and gas pipes and cabinetry shall be permitted when such obstructions are located within two feet of a partition or wall, do not interfere with normal ingress and egress, would not interfere with an emergency ingress or egress, and are approved by the inspector. Obstruction of ceiling space shall be permitted when such obstruction is located at a height of not less than six feet, four inches from the floor and which does not occupy more than 25 percent of the cubic area of the space within a room further than six feet, four inches from the floor.

12. Fire Protection Equipment. All fire extinguishers and early warning fire protection systems shall be properly installed according to the City Fire Code.

Ord. 2019-458 as incorporated in the city's chapter file, adopted May 7, 2019; in effect on publication (May 21, 2019) · source page

Confirmed by the city's current text: the 2026 draft recodification (August 2026, not adopted) has the same words (§ 156.17, p. 338), apart from minor wording.

In the 2026 draft (a comparison with a draft, not adopted): § 156.17 — wording changed, minor wording · compare

History

FromToSourceHowDocument
Aug 11, 2010May 21, 2019 2010 Code base text not available p. 11
Feb 28, 2013 Ord. 2013-322 amended in part · restated later, not consolidated p. 12
May 21, 2019today Ord. 2019-458 amended in part (text from the city file) · text p. 10

Dates: an Iowa ordinance takes effect when it is published after adoption. Where the clerk's certificate records the publication date it is used; otherwise the adoption date stands in for it. "Not yet consolidated" means the ordinance amends this section but its new text has not been checked into this compilation yet: read the ordinance.

Back to the chapter

Data last updated October 22, 2026. Built from the archive's documents; see how the data is built.