other

WS - C - Concept Design - Programming Summary

Dated October 18, 2022City Council — work session, October 18, 2022 3 pages

Open the PDF

Page 1 of 3

Text from the PDF text layer; check the PDF for anything that matters.
TIFFIN EMERGENCY MANAGEMENT FACILITY - UPDATED 9/26/2022 QTY SF PROGRAM DESIGN COMMENTS EMA STORAGE FACILITY Vehicle Storage 1 14,500 14,500 14,500 Five, double-deep drive through bays, all at 14' x 14' with no glass in doors Unisex Restroom with Shower 1 72 72 72 General restrooms can be located in shared areas Mechanical 1 500 500 500 Anticipated per owner meeting on 6/30 SUBTOTAL - EMA STORAGE 15,072 15,072 GROSS FACTOR 0% 0 Assumed 0 for vehicle storage TOTAL - EMA STORAGE 15,072 15,072 ADMINISTRATIVE AND TRAINING (SHARED) Entrance Vestibule 1 100 100 112 Assumed to be 10' x 10' entrance vestibule - Consider designing as a safe room Lobby and Reception 0 100 0 392 Not required - Consider visibile area incorporating opportunities for future heritage display Conference 2 352 704 704 Assumed 16' x 22' for 10-12 occupants per room - Smaller meeting rooms, size and quantity to be confirmed Multi-Purpose Room 1 1,500 1,500 1,296 ICC 500 - Large room for training and community meetings, 100 people in chairs at 15 SF / person, include kitchenette, could be in basement Multi-Purpose Restroom 1 64 64 96 ICC 500 - Single-use 8' x 8' family restroom - Final quantity to be determined Multi-Purpose Storage 1 200 200 288 ICC 500 - Final size to be determined Multi-Purpose HVAC 1 240 240 288 ICC 500 - Final size to be determined, includes janitor closet with mop sink, mop storage, and utility shelving Restroom - Typical 2 240 480 432 Assumed standard male and female, large multi-use restrooms at around 10' x 24' with (2) lavatories, (3-4) fixtures - Final design to be determined Restroom - Gender Neutral 1 64 64 0 8' x 8' with toilet and sink Janitor 0 50 0 0 Included in Multi-Purpose HVAC Fitness 1 400 400 648 Simple, modest, assumed to be 20' x 20' - First level is ideal, remote from Dorms due to noise Evidence Storage 0 80 0 0 Not provided New Mom's Room 0 80 0 0 CONFIRM if required - Best Practice: 1 per 200 Users in public facility, requires lockable door, water, and refrigerator Emergency Triage Room 0 80 0 0 CONFIRM if required - Could be combined with New Mom's Room Isolation Room 0 80 0 0 CONFIRM if required - Isolation room for mental heatlh purposes - Could be combined with New Mom's Room Vending 0 50 0 0 CONFIRM if required - 5' x 10' area for (2) vending machines - Could be combined with Kitchenette Kitchenette 0 80 0 0 Located in Multi-Purpose Room - Confirm if separate area is required SUBTOTAL - ADMINISTRATION AND TRAINING 3,752 4,256 RESIDENTIAL Sleeping Rooms 8 120 960 960 Assumed (8) rooms, carpet, blackout shades, (3) two-way wardrobe closets, size to discourage over use - Adjacencies: Not over or near day room, close to apparatus bay, isolate from sources of noise - street, fitness, apparatus bay Restrooms 4 72 288 320 Individual gender neutral restrooms with toilet, sink, locker(s), and large shower with seat and shelves Day Room 1 1,248 See spaces below for individual requirements Day - Kitchen 1 300 300 0 Full Kitchen with (3) refrigerators - res vs com, (3) pantries, commercial hood and stove, cabinets, large island - Included in overall Day Room SF Day - Dining 1 400 400 0 Large dining table for family meals - Sometimes built by fire fighters - Included in overall Day Room SF Day - Lounge 1 800 800 0 Day Room with (9) lounge chairs (OFOI), TV (OFOI) - Consider response times - Included in overall Day Room SF Office 2 120 240 240 Assumed to be 10' x 12' - Consider future growth Office 0 100 0 200 Assumed to be 10' x 10' - Consider future growth Watch Room 1 200 200 200 (3) workstations at continuous counter, could be U-shaped - Adjacencies: Visibility of apparatus bay Lieutenant Office 0 120 0 0 Assume not required - Adjacencies: Visibility of apparatus bay Work Room 1 96 96 96 8' x 12' galley style for office supplies, copier, mail, trash, recycle Electrical 1 50 50 0 5' x 10' electrical closet - Final size and location to be determined IT 1 80 80 120 Assumed 8' x 10' space for server and communication equipment, fire treated plywood on all walls Laundry, Storage, and Janitor 1 200 200 192 Combined space - See below for individual requirements Laundry 0 80 0 0 Space for washer (OFOI) - res vs com, dryer (OFOI) - res vs com, utility sink, casework - May be combined with Janitor and Storage Storage 0 80 0 168 Space for building attic stock storage Janitor 0 80 0 0 Space for mop sink, mop storage, utiltiy shelving - Combined above SUBTOTAL - RESIDENTIAL 3,614 3,744

Sources

  • sharepoint (WS - C - Concept Design - Programming Summary.pdf) — where it was found ↗ first seen Oct 12, 2026

This document's details as JSON

Data last updated October 15, 2026. Built from the archive's documents; see how the data is built.