other · C
Discussion and Review of Tiffin Municipal Code Revisions – Preparation for Setting the Public Hearing — Tiffin City Code - DRAFT
Document 280
Dated September 15, 2026City Council — work session, September 15, 2026 718 pages
Ord. 1983-117, Ord. 2018-437, Ord. 2010-302, Ord. 2012-309, Ord. 2007-288, Ord. 2012-313, Ord. 2007-287, Ord. 2018-433, Ord. 2019-446, Ord. 2012-319, Ord. 69
Page 538 of 718
Text from the PDF text layer; check the PDF for anything that matters.CHAPTER 166 ESTABLISHMENT OF ZONING DISTRICTS AND THE OFFICIAL ZONING MAP
Impact Vibration
Impact
Frequency DisplacementA (in.)
DisplacementA (in.)
(Maximum Adjacent
(Cycles per second) (Maximum Adjacent
Commercial and
Residential Uses)
Industrial Uses)
30-39 0.0004 0.0001
40-over 0.0002 0.0001
A
Impact vibrations, for purposes of this Code, are vibrations that
occur in discrete impulses separated by the interval of at least one
minute and numbering not more than eight in any 24-period.
(3) Smoke and Particulate Matter. The emission, from all
sources within any lot, or particulate matter containing more than five
percent by weight of particles having a particle diameter larger than
44 microns is prohibited. Dust and other types of air pollution borne
by the wind from such sources as storage areas, yards, and roads
within the boundaries of any lot shall be kept to a minimum by
appropriate landscaping, paving, oiling, or other acceptable means.
Emission of particulate matter from such sources in excess of the
weight limitations specified herein is prohibited. The emission of
smoke or particulate matter of a density or equivalent opacity equal
to, or greater than, Ringelmann Chart No. 2 is prohibited at all times,
except as otherwise provided herein. (The Ringelmann Chart is the
chart published by the United States Bureau of Mines.)
a. Smoke Emission. In the C-2 District, the emission of
more than 12 smoke units per stack in any one-hour period
is prohibited. However, once during any six-hour period
each stack must be permitted up to 12 additional units in a
15-minute period for soot blowing and fire cleaning. Only
during such 15-minute periods shall smoke of a density or
equivalent opacity equal to, but not exceeding, Ringelmann
Chart No. 3 be permitted, and then only for fire cleaning and
for not more than four minutes per period.
b. Particulate Matter. The rate of emission of
particulate matter from all sources within the boundaries of
any lot must not exceed the rate established in the following
table:
Maximum Permitted Particulate Matter Emission Rate
Pounds per Acre
Height of Emissions (ft)
(Per Acre)
0-49 1.00
50-99 1.01
100-149 1.06
150-199 1.10
200-299 1.16
300-399 1.30
400-over 1.50
CODE OF ORDINANCES, TIFFIN, IOWA
- 1658 -
Sources
- revize: Tiffin City Code - DRAFT (gFbbE0YR86eHDItZtXhZZqxLfknUlz.pdf) — where it was found ↗ first seen Oct 12, 2026
Attached to agenda item: C Discussion and Review of Tiffin Municipal Code Revisions – Preparation for Setting the...
Data last updated October 22, 2026. Built from the archive's documents; see how the data is built.